25
telephone number from 2 to 6
11. Control Panel Communication Code
Communication between control panel and center stations have two
formats ADEMCO 4+1 and ADEMCO Contact ID.
4. Notice before using
Please set '911' as alarm phone number under the police's approval.
Read the manual carefully before using
ADEMCO 4+1 Table of event
codes NO. Identification
ADEMCO Contact ID OPERATION OF
USER ARM/DISARM Number
Connect the AC power supply after other wiring is complete
Please use backup power when AC power failure
No.
1
2
3
DEFINITION
Fire alarm, including fire alarm
gas and panic zone
Plunder alarm, duress zone
Rob alarm, Entry/Exit /Active/
Perimeter/Anti-tamper zone
00
01
02
Operation of using keypad
without password, such as arm-
away disarm and arm-stay
User password to arm/disarm, by
using keypad or remote telephone
operation
Corresponding operation password
to arm/disarm by using keypad or
remote telephone operation
Do not disassemble the control panel and detector frequently
Any questions, please contact with our company
5. Installation step
5.1 Installation requirements
Work out a protection scheme based on user requirements, then decide
4
5
Disarm
Arm
11
21
15
Remote controller arm/disarm
Disarm/arm operation by using
the type and of the detector
Confirm the installation position and wiring direction according to the
specific condition. Make sure the position invisible without affecting its
Using duress code to disarm, the
reliability. It is better to wire in concealed way
6
7
AC power failure
Low-battery
98
system will be disarmed and then
send duress alarm information to
the center stations, the NO. of the
duress code user is 98 which
The construction scheme and engineering drawings must be filed for
maintenance late
included in the disarm information
8
Restore default
99
Auto-arm/auto-disarm
5
.
2 Inner wiring
Open the case of the control panel
ADEMCO Contact ID TABLE OF EVENT CODES
No.
DEFINITION
100
110
121
131
132
134
137
151
301
302
401
441
455
521
570
Panic zone alarm
Fire zone alarm
Duress code, Duress zone alarm
Perimeter zone alarm
Active zone alarm
Entry/Exit zone alarm
Control panel anti-tamper alarm. Anti-tamper zone alarm
Gas zone alarm
AC power failure
Low-battery
Arm/Disarm operation
Arm-stay operation
Auto-arm/disarm failing
Bell canceling function
Zone bypass operation, zone/user is 99 represent all
zones bypassed or all zones bypass canceling
-30-
Open outlet door for inserting cables
Outlet slot
Figure 1
Press those two points and
open the back cover
Figure 2
-3-