Types of fault
Potential reasons
Solutions
The system has no
feedback when zone is
touched
The zone is bypassed
Cancel bypass of the zone
When disarm, zone 1,2,3 do
not alarm; arm-stay zone 2
does not alarm
Operate normally
A u t o - a r m / a u t o - d i s a r m
invalidation
Arm/disarm is not set in valid
statue
Set arm/disarm in valid
status
Arm/disarm with the same time Reset the arm/disarm time
Can't disarm when alarm
occurs or the system is in
entry-delay status
Refer to Auto-arm/auto-
disarm
Wireless zone misinformation
Different wireless zones use
the same code learn
Cancel this wireless zone;
change the code learn
and try again
1. General introduction
This is a new kind of intelligent security product. It transmits alarm information
via telephone communication network and is remotely controlled to deal
with emergencies in time, ensuring user's personal and property safety.
This product has complete functions, flexible configuration; strong
destroy protection and convenient operations, being suitable for
residences, stores, factories, warehouses, banks, schools and hospitals,
etc.
2. Specifications
20 Fully programmable zones: 16 wireless and 4 wired
LCD displays
14. Technical parameter
14.1 General data
1. Requirement of wired zone: connect to 2.2K resistance
2. Control device:
R
emote controller
Keypad
Local or remote telephone system
3. Wireless frequency: 315MHz/ 433MHz/868 MHz(optional)
Communication protocol: ADEMCO 4+1 and Contact ID
Automatically dial center stations user cell phone or fixed telephone with
voice alarm while alarm occurs
6 alarm received telephones: 1 in center stations and 5 common
telephones
7 passwords: 1User, 1Duress, 5 Operation
Wireless code learn
Suppose to 5 remote controllers utmost
Arm or disarm via remote controller, telephone or keypad
4. Received range of the detector:
90m (in open space)
Alarm modes: alarm bell and voice alarm
5. Effective range of the remote controller:
6. Length of recording: 4 seconds
7. Dialing mode of alarm: DTMF
8. Relay output parameter:
Contact capacity 10VA
Contact maximal voltage 100VDC
Contact maximal current 0.5A
14.2 Other data
1. Power adapter working voltage: 100V
50m (in open space)
240V AC
Auto-arm and Auto-disarm time programable
Bypass/Reactivate stay zone type programable
Restore user password to factory default by hardware and restore the
system factory default by software
40 Events log
System supervision for AC power failure, low battery condition and
telephone line trouble
Real-time clock
Voice-recording
Programmable relay output
2. Operating voltage of the control panel: 12VDC
Anti-tamper
3. Static operating current:
130mA
Spot supervision
4. Bell output current:
400mA
5. Operating temperature: -10
+55
-32-
-1-