FLOOR COMBUSTIBLE
OPEN FRONT
1" (25.4 MM)
MINIMUM CLEARANCE
AROUND VENT PIPE
1/4" (6.35MM)
MINIMUM CLEARANCE
AROUND HOT WATER PIPES
RIGHT
0"
LEFT
0"
0"
FRONT
REAR
0"
0"
DIR #2000586144
PUMP ACCESS
COVER
Figure 1-2
Alcove Installation - Minimum Required Clearances
6"
6"
1/4" (6.35MM)
MINIMUM CLEARANCE
AROUND HOT WATER PIPES
1/4" (6.35MM)
MINIMUM CLEARANCE
AROUND HOT WATER PIPES
VENTILATING
AIR OPENING
VENTILATING
AIR OPENING
CLOSED DOOR
FLOOR COMBUSTIBLE
REAR
FRONT
LEFT
RIGHT
0"
0"
0"
0"
0"
DIR #2000586144
PUMP ACCESS
COVER
Figure 1-1
Closet Installation - Minimum Required Clearances
⚠
WARNING
9
1
Determine water heater location
(continued)
RECOMMENDED SERVICE
CLEARANCES:
Top
- 18" (457 mm)
Left/Right Side - 24" (610 mm)
Front - 24" (610 mm)
RECOMMENDED SERVICE
CLEARANCES:
Top
- 18" (457 mm)
Left/Right Side - 24" (610 mm)
Front - 24" (610 mm)
Installation & Service Manual
⚠
WARNING
For closet installations, CPVC,
polypropylene or stainless steel
vent material MUST BE used in
a closet structure due to elevated
temperatures. Failure to follow
this warning could result in fire,
personal injury, or death.
For alcove installations, CPVC,
polypropylene or stainless steel
vent material MUST BE used
in an alcove structure due to
elevated temperatures. Failure to
follow this warning could result
in fire, personal injury, or death.
Содержание Shield SWA150
Страница 53: ...53 Figure 9 2 Operating Instructions Models 125 285 9 Start up continued Installation Service Manual ...
Страница 54: ...54 Figure 9 3 Operating Instructions Models 400 500 9 Start up Installation Service Manual ...
Страница 82: ...82 Notes ...
Страница 83: ...83 Notes ...
Страница 84: ...Revision Notes Revision A PCP 3000038210 CN 500026403 initial release MM 100329111_DIR 2000585724 Rev A 04 20 ...