FAULT
DESCRIPTION
CORRECTIVE ACTION
OUTLET SENSOR
FAULT
(will require a manual
reset once the condition
has been corrected.
Press the RESET
button on the display to
reset.)
One or both of the outlet sensors has
opened or shorted.
• Check the sensor and its associated wiring. Repair or
replace the sensor or wiring if damaged.
• Measure the resistances of the sensors and compare
the resistances to the tables on page 70. Replace if
necessary.
INLET SENSOR
FAULT
(will require a manual
reset once the condition
has been corrected.
Press the RESET
button on the display to
reset.)
The inlet sensor is open.
• Check the sensor and its associated wiring. Repair or
replace the sensor or wiring if damaged.
SET POINT MET
The temperature has reached the set point
+ 10°F.
• None
ANTI-CYCLING
The main control board has received a call
for heat too quickly after the previous call for
heat has ended.
• The control board will release the call for heat after 60
seconds.
• The control board will release the call for heat if the
outlet temperature drops 10°F.
DELTA T HIGH
The temperature rise across the heat
exchanger has exceeded the set parameters
for the water heater.
• Verify that the system is full of water and that all air
has been properly purged from the system.
• Verify that the water heater is piped properly into
the heating system. Refer to Section 5 - System
Piping for the proper piping methods for the Shield
water heater.
• Check for 120 vac to the water heater pump motor
on a call for heat. If voltage is not present, check
the wiring back to the main control board. Replace
the main control board if necessary.
• If 120 vac is present on a call for heat and the water
heater pump is not operating, replace the pump.
• Verify that the water heater pump is set to the
proper speed or that the pump is the proper size.
Reference Section 5 - System Piping for water heater
pump specifications.
The fan speed is being limited due to the
temperature rise across the heat exchanger
exceeding 55°F.
Содержание Shield SWA150
Страница 53: ...53 Figure 9 2 Operating Instructions Models 125 285 9 Start up continued Installation Service Manual ...
Страница 54: ...54 Figure 9 3 Operating Instructions Models 400 500 9 Start up Installation Service Manual ...
Страница 82: ...82 Notes ...
Страница 83: ...83 Notes ...
Страница 84: ...Revision Notes Revision A PCP 3000038210 CN 500026403 initial release MM 100329111_DIR 2000585724 Rev A 04 20 ...