Field wiring
ELECTRICAL SHOCK HAZARD – For
your safety, turn off electrical power supply
before making any electrical connections
to avoid possible electric shock hazard.
Failure to do so can cause severe personal
injury or death.
Wiring must be N.E.C. Class 1.
If original wiring as supplied with the
water heater must be replaced, use only
type 105°C wire or equivalent.
The water heater must be electrically
grounded as required by National
Electrical Code ANSI/NFPA 70 – latest
edition.
Installation must comply with:
1. National Electrical Code and any other national, state,
provincial, or local codes, or regulations.
2. In Canada, CSA C22.1 Canadian Electrical Code Part 1, and
any local codes.
Power cord connection
This water heater is designed to operate with 120 VAC and 60
Hz power supply. If allowed by local codes, connect the power
cord provided with the heater to a GFI protected outlet on a
separate circuit and breaker (15 amp recommended). Ensure
the circuit cannot be interrupted by a switch used to control
lights or other appliances.
If local codes do not allow for the use of the power cord, remove
the cord from the junction box found on the side of the control
support bracket (FIG. 7-2) and attach conduit to the junction
box. Route the wires out of the appliance to a GFI protected
outlet on a separate circuit and breaker (15 amp recommended).
Label all wires prior to disconnection
when servicing controls. Wiring errors can
cause improper and dangerous operation.
Verify proper operation after servicing.
⚠
WARNING
NOTICE
⚠
CAUTION
LOW VOLTAGE
WIRING PLUGS
DIR #2000586621
Figure 7-1
Routing Field Wiring
Enable switch
An external switch or contact may be used to enable/disable
the water heater. To connect the enable switch, remove
jumper tab "A" on the low voltage connection board and
connect the wires from the switch to the correct terminals.
Reference Fig 7-3 on page 47 of this manual for appropriate
wiring of the switch. If the incorrect tab is removed, a jumper
wire may be added across the terminals to take the place of
the tab.
Louver relay output / louver proving
switch input
When installed using the optional room air configuration,
the heater is able to control powered louvers to allow outside
air into the room. Connect the 24VAC control relay to the
LOUVER RELAY output on the low voltage connection
board. Remove jumper tab "B" on the low voltage connection
board and connect the louver proving switch wires to the
correct terminals. Reference Fig 7-3 on page 47 of this
manual for appropriate wiring of the switch. If the incorrect
tab is removed, a jumper wire may be added across the
terminals to take the place of the tab.
Low voltage connections
1. Route all low voltage wires through the plugs in the top
of the water heater, as shown in FIG. 7-1.
2. Connect low voltage wiring to low voltage connection
board as shown in FIG. 7-3 on page 47 of this manual and
the water heater wiring diagram.
Runtime contacts
The electronic control closes a set of dry contacts whenever
the burner is running. This is typically used by Building
Management Systems to verify that the water heater is
responding to a call for heat.
Alarm contacts
The electronic control closes another set of contacts whenever
the water heater is locked out or the power is turned off.
This can be used to turn on an alarm, or signal a Building
Management System that the water heater is down. Note that
the alarm contacts will close momentarily after each call for
heat.
Installation & Service Manual
MODELS 125- 200
DIR #2000586621
JUNCTION BOX
POWER CORD
JUNCTION BOX
MODELS 285-500
DIR #2000586621
POWER CORD
Figure 7-2
Remove Power Cord
Use of an extension cord is NOT allowed. If
a suitable electrical outlet is not within reach
of the supplied power cord, a new receptacle
must be installed or the power cord must
be replaced with hard conduit as described
above.
⚠
WARNING
Содержание Shield SWA150
Страница 53: ...53 Figure 9 2 Operating Instructions Models 125 285 9 Start up continued Installation Service Manual ...
Страница 54: ...54 Figure 9 3 Operating Instructions Models 400 500 9 Start up Installation Service Manual ...
Страница 82: ...82 Notes ...
Страница 83: ...83 Notes ...
Страница 84: ...Revision Notes Revision A PCP 3000038210 CN 500026403 initial release MM 100329111_DIR 2000585724 Rev A 04 20 ...