22
2
General
venting
Installation & Service Manual
Figure 2-10
Near Water Heater Stainless Steel Venting
Table 2G
Approved Stainless Steel (S.S.) Terminations and Adapters
The installer must use a specific vent
starter adapter at the flue collar connection,
supplied by the vent manufacturer to
adapt to its vent system. See Table 2G for
approved vent adapters. Discard CPVC
starter piece.
NOTICE
Approved Stainless Steel Vent Manufacturers
Make
Model
Standard
Duravent (M & G Group)
FasNSeal
UL 1738/ULC-S636
Dura Vent (M & G Group)
FasNSeal Flex* Vent
UL 1738/UL 1777/ULC-S636
Z-Flex (Nova Flex Group)
Z-Vent
UL 1738/ULC-S636
Heat Fab (Selkirk Corporation)
Saf-T Vent
UL 1738/ULC-S636/UL 641/ULC-S609
Metal Fab
Corr/Guard
UL 1738/ULC-S636
Security Chimney
Secure Seal
UL 1738/ULC-S636
Table 2F
Stainless Steel Vent Pipe and Fittings
*Use of FasNSeal Flex smooth inner wall vent is to be used in
vertical or near vertical sections only, taking precaution to ensure
no sagging occurs of the vent system. Connect to the FasNSeal
rigid vent using specially designed adapters and sealing method, see
manufacturer’s instructions.
Stainless steel vent
This product has been approved for use with stainless steel
using the manufacturers listed in Table 2F. This unit requires
Category IV venting.
Use only the materials, vent systems, and
terminations listed in Tables 2F and 2G.
DO NOT mix vent systems of different
types or manufacturers. Failure to comply
could result in severe personal injury,
death, or substantial property damage.
⚠
WARNING
Installations must comply with applicable
national, state, and local codes. Stainless
steel vent systems must be listed as a
UL-1738 approved system for the United
States and a ULC-S636 approved system
for Canada.
NOTICE
Installation of a stainless steel vent system
should adhere to the stainless steel vent
manufacturer’s installation instructions
supplied with the vent system.
NOTICE
Model
ProTech
Heat Fab
Z Flex
FasNSeal
Saf-T Vent
Z-Vent
S.S.
Adapter
Flue
Termination
Intake
Air
Termination
S.S.
Adapter
Flue
Termination
Intake
Air
Termination
S.S.
Adapter
Flue
Termination
Intake Air
Termination
125 -- 200
300715
FSBS3
FSRC3(R.C)
303889
9301PVC
9392
5300CI
9314TERM 2SVSLA03 2SVSTP03
2SVSRCX03 2SVSTEX0390
285 -- 500
F303759
FSBS4
FSRC4(R.C.)
FSAIH04
303888
9401PVC
9492
5400CI
9414TERM 2SVSLA04 2SVSTP04
2SVSRCX04 2SVSTEX0490
Metal Fab
Security Chimney
Corr/Guard
Secure Seal
125 -- 200
3CGIA
3CGSWHT
3CGSWC
3CGSW90LT
--
--
--
285 -- 500
4CGIA
4CGSWHT
4CGSWC
4CGSW90LT SS4PVCU
SS4STU
SS4RCBU SS4ST90AU
3" S.S. ADAPTER
4" S.S. ADAPTER
MODELS 125 - 200
MODELS 285- 500
DIR #2000586659
Содержание Shield SWA150
Страница 53: ...53 Figure 9 2 Operating Instructions Models 125 285 9 Start up continued Installation Service Manual ...
Страница 54: ...54 Figure 9 3 Operating Instructions Models 400 500 9 Start up Installation Service Manual ...
Страница 82: ...82 Notes ...
Страница 83: ...83 Notes ...
Страница 84: ...Revision Notes Revision A PCP 3000038210 CN 500026403 initial release MM 100329111_DIR 2000585724 Rev A 04 20 ...