Troubleshooting, continuation
Fault: Blockage in the downstream progressive system, continuation
Cause: Correction:
Metering device blocked
Â
Thoroughly rinse metering device with a manual pump.
Â
If not possible, replace the metering device.
Â
Remove all tube fittings.
6001a02
IMPORTANT
The control pistons are fit into the metering
device bores. They must not be mixed up.
Fault: Differing lubricant amounts at the lubrication points
Cause: Correction:
Lubricant metering not correct
Â
Check the lubricant metering acc. to the lubrication chart.
Setting of the pause time or operating time incorrect
Â
Check the time setting.
Fault: Excessive or poor lubrication of the lubrication points
Cause: Correction:
Setting of the operating time or pause time incorrect
Â
Check the time setting at the control devices, printed circuit
boards or control units.
Tab. 1
Troubleshooting
Selection Guide
Examples of model designations
Standard designation
Expanded designations
SSVD 6
SSVD
14/13 - V1
-
K
SSVD
8 - ABCF
SSVD
14 - S - ACBGABC - N - RV6 / WEKV6 / outlets
3,
6,
8,
10
Series
Number of outlets
Type of outlet tube fitting
Metering device crooked
Metering possibilities
A = 0.07 ccm
F = 0.6 ccm
B = 0.14 ccm
G = 0.8 ccm
C = 0.2 ccm
H = 1.0 ccm
D = 0.3 ccm
I = 1.4 ccm
E = 0.4 ccm
J = 1.8 ccm
Monitoring
Outlet tube fittings
Inlet tube fittings
Closed outlets