![Lincoln Quicklub SSV D Series Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/lincoln/quicklub-ssv-d-series/quicklub-ssv-d-series_operating-instructions-manual_1917732029.webp)
Subject to modifications
User Manual
Operating Instructions
2.2A-20003-B07
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Page 1 of 26
Table of Contents
Page
Introduction
..................................................................... 2
Explanation of Symbols Used ............................................ 2
User’s Responsibility ......................................................... 2
Environmental Protection .................................................. 2
Service .............................................................................. 2
Safety Instructions
Appropriate Use ................................................................ 3
General Safety Instructions ............................................... 3
Regulation for Prevention of Accidents ............................. 3
Operation, Repair and Maintenance .................................. 3
Installation ......................................................................... 3
Installation
Tube Fittings, Screw-Type ................................................. 4
Main and secondary metering devices ........................ 4
Tube Fittings, Push-in Type ............................................... 4
Metering devices .......................................................... 4
Check
valves ................................................................
4
Connection of high-pressure
and pressure plastic tube ............................................. 5
- High-pressure range .................................................. 5
- Low-pressure range ................................................... 5
- Protective cap for push-in type fittings ....................... 5
Pressure Plastic Tubes and High-pressure Hoses ............ 6
Description
Progressive Metering Device Model SSV D ...................... 7
Progressive Plunger Metering Devices, General ......... 7
Features of a Progressive Metering Device ................. 7
Function Principle and Reliability ................................. 7
Further information can be found in the following manu-
als:
Technical Description QUICKLUB - Pump 203
Technical Description for “Electronic Control Units” of Pump
203:
Printed-Circuit Board 236-13857-1 - Variant H
1)
Printed-Circuit Board 236-13862-1 - Variant V10 - V13
1)
Printed-Circuit Board 236-13870-1 - Variant M 08 - M 15
1)
Printed-Circuit Board 236-13870-1 - Variant M 16 - M 23
1)
Installation Instructions
Parts Catalog
1)
The model designation of the printed-circuit board is part of
the pump model designation indicated on the pump name-
plate. Example: P 203 - 2XN - 1K6 - 24 - 1A1.10 -
V10
Page
Operation
Lubricant Distribution within the Metering Device .............. 8
General
........................................................................
8
Metering Screws ........................................................... 8
When the lubricant supply is interrupted ....................... 8
Phase 1 + 2 .................................................................. 9
Phase 3 + 4 ................................................................ 10
Phase 5 + 6 ................................................................ 11
Phase 7 + 8 ................................................................ 12
Phase 9 + 10 .............................................................. 13
Phase 11 + 12 ............................................................ 14
Cross-porting of outlets, internal ................................. 15
Cross-porting of outlets, external ................................ 15
Monitoring of the Operation
System-dependent monitoring .................................... 16
Visual monitoring ........................................................ 16
Electrical monitoring ................................................... 17
Pressure relief valve ................................................... 17
Adjusting the Output by Using Metering Screws .............. 17
Adapting the Lubricant Output by Cross-porting of Outlets
Tube Fittings, screw type ........................................... 18
Tube Fittings, push-in type
(Main or secondary metering devices) ....................... 19
Troubleshooting
............................................................. 20
Selection Guide
.............................................................. 21
Technical Data
Metering Devices ............................................................. 22
Push-in Type Fittings ....................................................... 22
Lines ................................................................................. 22
Tightening Torques .......................................................... 22
Metering Screws .............................................................. 22
Dimensions ...................................................................... 23
Metering device model SSV D 6 to SSV D 22 ............ 23
List of Lubricants
........................................................... 24
Proven lubricants ............................................................. 24
Lubricant recommendations based on the
manufacturer’s data sheet ............................................... 25
Biodegradable lubricants ................................................. 26
Lubricants for the food & beverage industry .................... 26