Operation
Lubricant Distribution within the Metering Device
6143b05
&
6144b05
Fig. 11
Schematic drawing and view from the left to the metering
device
I -
control piston level
II -
metering piston level
III -
outlet level
1 - 6 outlet number
A – C pair of pistons (metering and control piston)
a
1
– c
1
metering piston
a
2
– c
2
control piston
DA - metering screw for metering piston A
DB - metering screw for metering piston B
DC - metering screw for metering piston C
f
-
piston closure plug (comp. Pos. 4, Fig. 26, page 18)
General
The illustrations fig. 12 to 18 show how the lubricant is dis-
tributed to each outlet.
6001a02
NOTE
To simplify the description we only show the
lubricant distribution for outlets 6, 4, 2, 5, 3
and 1. The remaining distribution operations
are derived from the logical pumping se-
quence.
Metering screws (DA, DB, DC) are always mounted on the
side with the even outlet numbers. On the side with odd outlet
numbers, closure screws are used only.
The SSV D has three functional levels. They are visible from
both sides due to three bore rows (see pos. I to III, Fig. 11):
I.
Control piston level (behind closure plugs)
II. Metering piston level
(medium level behind metering screws)
III. Outlet
level
(behind closure screws and connecting screws)
Metering Screws
6001a02
IMPORTANT NOTE
For each lube cycle, the output of the me-
tering piston (V1) and the control pis-
ton (V2) is dispensed on one outlet.
The metering piston stroke and the related
output can be adjusted by means of meter-
ing screws of different lengths.
Short metering screws allow for a long
stroke of the metering piston. I.e. with the
shortest metering screw you achieve the
maximum output.
The longest metering screw compresses
the metering piston completely, so that
only the lubricant quantity of the control
piston (0,08 cm³) is dispensed.
This metering has a proper impact on both
of the outlet bores:
Metering screw Pair of outlets
DB
6 and 5
DC
4 and 3
DA
2 and 1 (see Fig. 11)
NOTE
For the classification of the metering screw
lengths and their metering quantities, see
page 22, Tab. 3.
When the lubricant supply is interrupted
IMPORTANT
When the lubricant supply is inter-
rupted, please observe:
6001a02
-
-
The pistons come to a halt.
The lubricant is no longer dispensed to
the lubrication point.
When the lubricant is fed again to the metering device, the
cycle begins from the point where it had been interrupted.