Operation, continuation
Adapting the Lubricant Output by Cross-porting of Outlets
Tube fittings, screw type
1012b05
Fig. 26
Install the push-in type outlet fittings and the closure plugs in accordance with the dosage
1 -
Inlet fitting
4 -
Closure plug (M11 x 1),
piston
(with
chamfer)
8 -
Coupling nut
2 -
Delivery hole of the metering piston
and
control
piston
5 -
Outlet fitting assembly
(M10 x 1)
9 -
Junction channel
3 -
Metering screw (M10 x 1)
6 -
Valve body with clamping ring (brass)
10 - Closure plug with hex. socket head
7 -
Cutting ring
Apart from an adjustment by means of metering screws,
(see page 19) you may also increase the output by clos-
ing outlet bores.
Install an outlet fitting assembly (pos. 5, M 10 x 1) in each
outlet bore to be used.
Never remove closure plug
(pos. 4,
M11 x 1 cham-
fered
) on the piston side or remove it only for installing a
piston detector.
Clamping ring (pos. A, Fig. 28) closes the junction chan-
nels (pos. 9) to the other outlet channels.
6001a02
NOTE
In the case of push-in type fittings the
clamping ring is always a firm component
of the valve body (pos. 6).
IMPORTANT
In the case of the progressive metering
devices model SSV D 6 to SSV D 22,
outlets 1 and 2 must never be closed,
otherwise the system would block due to
the structure of the metering device.
In case of progressive metering devices
whose outlets 1 and 2 can be cross-ported,
one outlet must be closed. Thereby the
lubricant quantity of one outlet side may be
dispensed on the other side of the meter-
ing device.