Installation
Tube Fittings, Screw type
4239a99
Fig. 1
Single parts of the check valve
Main- and secondary metering devices SSV D
Inlet tube fittings, straight and 90°
As inlet fitting use only tube fittings R1/8” thread.
Check valves
Install one complete check valve in each outlet bore that will
be used, see fig. 1.
Install one closure plug in each outlet borehole that will not be
used. Exception: outlet bore 1 & 2 on SSV D 6 to SSV D 14.
Check valves must be installed in both bores.
1 -
coupling nut
2 -
ferrule
3 -
valve body with seal and
clamp ring
Tube Fittings, Push-in type
1008a98
Fig. 2
Inlet fittings
Metering devices
Inlet tube fittings, straight and 90 °
6001a02
IMPORTANT
For the inlet fittings use only tube fittings
with reinforced collet 1a (fig. 2) and
sealing ring 1b at the thread.
1a - Collet
1b - Sealing ring
1009a98
Fig. 3
The different types of check valve
Check valves
A check valve must be mounted to the corresponding
metering device outlet of each feed line in order to be able
to precisely meter the predefined amount of lubricant.
Main metering device
Use check valves type A, Fig.3 with reinforced collet 1a
and smooth flange (Part no. 226-14091-4).
Secondary
metering
device
Use check valves type B, Fig. 3 with standard collet 2a
and knurled flange (Part no. 226-14091-2).
6001a02
NOTE
On construction machines or agricultural
machines use high-pressure plastic hoses.
In such cases the check valves of the
secondary metering devices must have a
reinforced collet and smooth flange.
A -
Check valve with reinforced collet
B -
Check valve with knurled collet
1a - reinforced collet
2a - knurled collet