IP LDK-20 Programming Manual Quick
ADMIN Programming table
533
PGM FLEX
ITEM
RANGE
DEFAULT
REMARK
1
Call FWD No Answer Timer
000 – 255
(3 digits)
015
(sec)
This timer is used at the no answer call forward
feature(Section 2.3.1.2, and 2.3.1.3). If station
is set the no answer call forward type, and if
station don’t answer during this timer, then the
call will be routed to the forward destination.
2
DID/DISA No Answer Timer
00 – 99
(2 digits)
00
(sec)
This timer is used at DID or DISA call routing. If
station doesn’t answer about DID/DISA call
during this timer, the call will be routed to
ADMIN program 167 – FLEX 3 value.
3
VMIB User Record Timer
010 – 255
(3 digits)
020
(sec)
This is the maximum time that station user can
record his VMIB announcement.
4
VMIB Valid User Message
Timer
0-9
(1 digit)
4
(sec)
This is the minimum time that station user must
record his VMIB announcement.
If this value is set to 0, VMIB announcement
can not be recorded.
5
Door Open Timer
05 – 99
(2 digits)
20
(100ms)
Select the length of time that is needed to
execute the door open relay for the setting
time.
6
ICM Box Timer
00 – 60
(2 digits)
30
(sec)
Select the ringing time of the ICM box
associated stations, when ICM box user press
[CALL]
button.
7
ICM Dial Tone Timer
01 – 20
(2 digits)
10
(sec)
This timer is used when the off-hooked station
is heard the intercom dial tone. If station
doesn’t dial a digit within this timer, error tone is
provided.
8
Inter Digit Timer
01 – 20
(2 digits)
05
(sec)
This timer is used when station is dialing some
digits. The time between digits cannot exceed
Inter-digit timer, or error tone is provided.
9
MSG Wait Reminder Tone
Timer
00 – 60
(2 digits)
00
(min)
Select the amount of time between repeated
reminder tones to station that it has a message
waiting.
10
Paging Timeout Timer
000 – 255
(3 digits)
000
(sec)
Select the maximum time of a page. The
system will automatically disconnect the page
at the end of this time unless the caller has
hung up earlier.
11
Pause Timer
1 – 9
(1 digit)
3
(sec)
This timer is used at the speed dialing feature,
LNR, and etc. In case of the speed dial or LNR,
IP LDK system sends the dial digits to the
outgoing CO line, after this time.
12
Preset Call Forward Timer
00 – 99
(2 digits)
10
(sec)
This timer is used at the preset call forward
feature(Section 2.3.1.9). After this timer expires,
incoming call will be forwarded to a
predetermined station.
13
SLT DTMF Release Timer
00 – 20
(2 digits)
00
(sec)
DTMF RCVR will be released after this timer
when SLT makes a outgoing CO call.
14
3 soft auto release timer
01 – 30
(2 digits)
05
(sec)
This timer is used only in 3soft BTN DKTU(LDH-
30DH). In 3soft menu, if there is no any digit
within time, the DKTU turn to Idle state.
15
VM pause timer
01 – 90
(2 digits)
30
(100ms)
In-band digit stream is sent to external VM after
this timer.
16
Transit Connect Tmr
1 – 30
04
Master sends the connect message to slave
system after this timer when the transit out CO
type is a pulse analog trunk.
181
17
VMIB msg Fwd/Rew(sec)
1 – 99
05
VMIB message is rewound as this timer.
Содержание IP LDK-20
Страница 202: ...IP LDK 20 Programming Manual System Feature 186 ...
Страница 211: ...IP LDK 20 Programming Manual System Feature 195 ...
Страница 213: ...IP LDK 20 Programming Manual System Feature 197 ...
Страница 472: ...IP LDK 20 Programming Manual ADMIN Programming 456 PROCEDURE 320 Value 2 Digit ...
Страница 514: ...IP LDK 20 Programming Manual ADMIN Programming 498 ...