IP LDK-20 Programming Manual System Feature
140
5. Pressing the
[CALLBK]
button, the current message is played again. For SLT and 2/8 BTN
DKTU, dial #3.
6. Pressing the
[ADD]
soft button, you can record the additional message.
(It can be possible LDP-6000/7000 which has 3 soft key)
7. Pressing the
[REWIND]
soft button, you can rewound the current message with VM MSG
Rewind Timer. ((It can be possible LDP-6000/7000 which has 3 soft key))
Condition
1. There is no time limit to record user greeting in a station.
2. When a caller leaves a voice message wait, the recording time is controlled by Valid User
Message Timer
(ADMIN program 181 – FLEX 4)
and VMIB User Record Timer
(ADMIN program
181 – FLEX 3)
. When the recorded message shorter than Valid User Message time, the message
is not saved. Also, the User Record Timer expires, confirmation tone is heard and the message is
saved in the station.
3. If the station has several messages to be retrieved by pressing the
[CALLBK]
button, the
message only with station number will be retrieved at first. (Message wait with station number ->
VMIB Message wait -> CLI Message wait -> VM group Message wait)
4. Pressing the
[CALLBK]
button at the calling station before user greeting is played, the message
wait with only station number is saved in the called station.
5. When a user calls a station which is forwarded to VMIB, he will hear user greeting and beep tone.
After beep tone, user can leave a voice message.
6. Each station may has max.2000 VMIB message waits.
7. If all the VMIB ports are busy, ring-back tone will be provided instead of user greeting. And VMIB
Station Forward Timer is started to retry to answer.
8. User can leave and receive message wait using SLT with message wait lamp.
9. Individual user greeting and VMIB message wait are protected with system reset.
10. To retrieve left message wait, the order of playing is changeable. Originally, TIME, DATE, and a
left message are played. If the ADMIN is set, DATE, TIME, and a left message are played.
11. To retrieve left message wait, the Message Wait Retrieve Password would be used by ADMIN. If
ADMIN PGM 113 & FLEX 8 is set, a user should enter that stations’ AUTHORIZE CODE to
retrieve.
12. When user listen to the message, user can rewind the message. Rewound Time is controlled by
Rewind Message Timer (PGM 181 – Flex 17)
Reference
1. Message Wait/Callback Return Code : 3.6.7(ADMIN 106 – FLEX 14)
Admin Programming
n
VMIB Message Type
4.1.2.17 (PGM 111 – FLEX 17)
n
VMIB Access
4.1.4.2 (PGM 113 – FLEX 2)
n
VMIB MSG Retrieve PASSWORD
4.1.4.8 (PGM 113 – FLEX 8)
n
VMIB MSG Retrieve Date/Time
4.1.4.9 (PGM 113 – FLEX 9)
n
Call Forward No Answer Timer
4.5.2.1 (PGM 181 – FLEX 1)
n
VMIB User Record Timer
4.5.2.3 (PGM 181 – FLEX 3)
n
VMIB Valid User Message Timer
4.5.2.4 (PGM 181 – FLEX 4)
n
VMIB Message Rewind Timer
4.5.2.17 (PGM 181 – FLEX 17)
Содержание IP LDK-20
Страница 202: ...IP LDK 20 Programming Manual System Feature 186 ...
Страница 211: ...IP LDK 20 Programming Manual System Feature 195 ...
Страница 213: ...IP LDK 20 Programming Manual System Feature 197 ...
Страница 472: ...IP LDK 20 Programming Manual ADMIN Programming 456 PROCEDURE 320 Value 2 Digit ...
Страница 514: ...IP LDK 20 Programming Manual ADMIN Programming 498 ...