IP LDK-20 Programming Manual Quick
ADMIN Programming table
528
PGM FLEX
ITEM
RANGE
DEFAULT
REMARK
1
LCD Time Display
Mode
12H / 24H
12H
Two LCD Time formats are Ordinary (12-hour)/Military (24-
hour) mode
2
LCD Date Display
Mode
MMDD /
DDMM
DDMMYY
Two LCD date formats are Day/Month/Year (DDMMYY) or
Month/Day/Year (MMDDYY) mode.
169
3
LCD Language
Display Mode
00-14
12(Korean) The LCD language format can be selected.
Modem Associated
Device
Modem service is available only when there’s MODU on
MPB.
1
Station Number
10-37
STA 37
This value means the Modem-associated station. To use
Modem line flexibly, associate one station with Modem.
Then incoming CO Call is connected to Modem device if the
station gets the call.
The last station is assigned as Modem associated station.
170
2
CO Number
01-12
-
If CO Line is associated with Modem, All of the incoming CO
Call through this Line is connected to Modem. The Modem-
associated CO Line cannot be used to outgoing CO Call.
1
BGM Type
0-8
01
2
MOH Type
0-9
01
When a CO line call is placed in the hold state (system,
exclusive, transfer, conference, etc) the external party will
hear music. In this way, the CO line party can be notified
that the connection is still established.
3
ICM
Box
Music
Channel
0-8
01
4
Assign
MOH
via
SLT
F1 – F5
To assign SLT MOH, set this value and match the SLT
station number of the SLT port.
5
DIAL TONE
SOURCE
0-5
0 (Not
Assign)
To assign external dial tone, set the SLT station number of
the SLT port.
6
ICM RING BACK
TONE
0-5
0(Not Assign)
To assign external ICM ring back tone, set the SLT station
number of the SLT port.
171
7
Reserved
172
1 - 4 PBX Access Code
Max. 2
digits
-
Maximum 4 PABX Access Codes can be assigned. Each
PABX Access Code is 1 or 2-digit number.
By default, PABX Access Codes are not assigned at all.
PLA Priority Setting
PLA priority is set exclusively
1
Transfer CO
1 – 4
1
2
Recalling CO
1 – 4
2
3
Incoming CO
1 – 4
3
173
4
Queued CO
1 – 4
4
RS-232
PORT
Setting
Baud Rate, CTS/RTS, P-Break, LPP can be assigned at this
feature to COM1 port, COM2 – MODU port.
1
BAUDRATE
0-7(Note1)
19200
0: UNKNOWN
1: UNKNOWN
2: 1200 BAUD
3: 2400 BAUD
4: 4800 BAUD
5: 9600 BAUD
6: 19200 BAUD
7: 38400 BAUD
2
CTS/RTS
ON / OFF
OFF
3
P-BREAK
ON / OFF
OFF
174
4
LPP
001-199
060
Содержание IP LDK-20
Страница 202: ...IP LDK 20 Programming Manual System Feature 186 ...
Страница 211: ...IP LDK 20 Programming Manual System Feature 195 ...
Страница 213: ...IP LDK 20 Programming Manual System Feature 197 ...
Страница 472: ...IP LDK 20 Programming Manual ADMIN Programming 456 PROCEDURE 320 Value 2 Digit ...
Страница 514: ...IP LDK 20 Programming Manual ADMIN Programming 498 ...