Technical data
Leuze electronic GmbH + Co. KG
BPS 307i
77
Tab. 13.2:
Measurement data
Reproducibility (1 sigma)
±0.05 mm
Output time
0.05 ms … 2 ms (configurable)
Default: 2 ms
Response time
8 ms (adjustable, factory setting 8 ms)
Basis for contouring error calculation
4 ms
Measurement range
0 … 10,000,000 mm
Resolution
0.1 mm (adjustable, factory setting 0.1 mm)
Max. traverse rate
10 m/s
Tab. 13.3:
Operating and display elements
Display (optional – only in device mod-
els with "D")
Monochromatic graphical display, 128 x 32 pixels,
With background lighting
Keyboard (optional – only in device
models with "D")
Two buttons
LEDs
Two LEDs for power (PWR) and bus state (BUS), two-colored
(red/green)
Tab. 13.4:
Mechanical data
Housing
Diecast aluminum
Connection technology
• BPS with MS 307: M12 connectors
• BPS with MK 307: Terminal blocks with spring-cage termi-
nals (5-pin)
• BPS with KB 307: cable connection
Degree of protection
IP 65
Weight
Approx. 580 g (without connection hood)
Dimensions of the BPS 307i without
connection hood
(H x W x D) 108.7 mm x 100.0 mm x 48.3 mm
Dimensions (with MS 307 connection
hood)
(H x W x D) 108.7 mm x 100.0 mm x 48.3 mm
Dimensions (with MK 307 connection
hood)
(H x W x D) 147.4 mm x 100.0 mm x 48.3 mm
Dimensions (with KB 307 connection
hood)
(H x W x D) 108.7 mm x 100.0 mm x 48.3 mm
Dimensions of MS 307 connection hood
(H x W x D) 64.0 mm x 43.5 mm x 33.5 mm
Dimensions of MK 307 connection hood
(H x W x D) 64.0 mm x 43.5 mm x 83.5 mm
Dimensions of KB 307 connection hood
(H x W x D) 64.0 mm x 43.5 mm x 18.1 mm
Tab. 13.5:
Environmental data
Air humidity
Max. 90% rel. humidity, non-condensing
Vibration
IEC 60068-2-6, test Fc
Shock
Continuous shock
IEC 60068-2-27, test Ea
Electromagnetic compatibility
IEC 61000-6-3
IEC 61000-6-2 (contains IEC 61000-4-2, -3, -4, -5, -6)