Device description
Leuze electronic GmbH + Co. KG
BPS 307i
13
NOTICE
The configuration switches and the integrated parameter memory for simple replacement of the
BPS are located in the MK 307.
1
2
1
1
1
3x cable bushing, M16 x 1.5
2
SERVICE: Mini-B USB socket (behind protective cap)
Fig. 3.3:
Connection hood MK 307, connections
Cable fabrication and shielding connection
Ä
Remove approx. 78 mm of the connection cable sheathing. 15 mm of sheath of the shielded line must
be freely accessible.
Ä
Lead the individual wires into the terminals according to the diagram.
NOTICE
Do not use wire-end sleeves!
Ä
When fabricating cables, we recommend against using wire-end sleeves.
NOTICE
The shield is automatically contacted when the cable is lead into the metal screw fitting and fas-
tened when the cord grip is closed.
≈ 55 mm
≈ 8 mm
≈ 15 mm
1
2
1
Diameter of contact area, cable: 6 … 9.5 mm
2
Diameter of contact area, shield: 5 … 9.5 mm
Fig. 3.4:
Cable fabrication for connection hoods with spring-cage terminals