Starting up the device – webConfig tool
Leuze electronic GmbH + Co. KG
BPS 307i
60
9.3
Short description of the webConfig tool
9.3.1
Overview
Operating modes
For configurations with the webConfig tool, you can switch between the following operating modes:
•
Process
The BPS is connected to the control.
• The process communication to the control is activated.
• The switching inputs/outputs are activated.
• Configuration and diagnostics functions available, cannot be changed.
•
PROCESS
function available.
• Alignment and maintenance functions not available.
•
Service
• The process communication to the control is interrupted.
• The switching inputs/outputs are deactivated.
• The configuration can be changed.
•
PROCESS
function not available.
• Alignment, configuration, diagnostics and maintenance functions available.
Process operating mode
In the
Process
operating mode, the webConfig tool has the following main menus and functions:
•
PROCESS
Check and save the current read data in process mode (see chapter 9.3.2 "PROCESS function").
• Tabular display of the following values:
Scan number, position, speed, reading quality, distance from BCB, info on the control label
•
CONFIGURATION
(see chapter 9.3.4 "CONFIGURATION function")
Information on the current BPS configuration – no change to the configuration:
• Display of the output modules (value formatting)
• Selection of the used bar code tape (30 mm grid or 40 mm grid)
• Display of the tape value correction (deviation of the BCB from scaling)
• Display of the device components (switching inputs/outputs, display)
• Data processing (position/speed detection or monitoring, data preparation)
• Display of the warning threshold and the error threshold for the reading quality
Service operating mode
In the
Service
operating mode, the webConfig tool also has the following main menus and functions:
•
ALIGNMENT
(see chapter 9.3.3 "ALIGNMENT function")
• Display of the following values:
Scan number, position, speed, quality, distance, number of labels in the scanning beam
• Graphical displays of the following values:
Position, speed, quality
•
CONFIGURATION
(see chapter 9.3.4 "CONFIGURATION function")
• Configuration of the output modules (value formatting)
• Configuration of device components (switching inputs/outputs, display)
• Selection of the used bar code tape
• Configuration of the data processing (position/speed detection or monitoring, data preparation)
• Configuration of the warning threshold and the error threshold for the reading quality