Starting up the device – webConfig tool
Leuze electronic GmbH + Co. KG
BPS 307i
64
• Status: Upper/lower position limit value ½
Signals a value above/below the position limit.
• Speed
Current speed of the BPS
• Status: Speed invalid
Signals that no valid speed can be ascertained.
• Status: speed limit value 1-4
Signals that speed limit value 1-4 has been exceeded or has not been met.
• Direction of movement
Signals the direction of movement of the BPS.
• Tape direction
Signals the orientation of the BPS to the BCB (0° or 180°).
• Status IO1, IO2
The status of the switching input/output is output.
Configuration of the switching inputs/outputs (
DEVICE
tab)
• I/O mode: switching input or switching output
• Output function
• Input function
• Time behavior functions
• Signal delay
• Pulse duration
• Switch-on/switch-off delay
• Debounce time
• Inversion yes/no
Configuring switching outputs
Ä
Select the function symbol for activation of the switching output in the
Functions
area.
Ä
Use the left mouse button to drag the function symbol into the
Activation
window.
Ä
Configure the timing; see "Time behavior functions of the switching inputs/outputs".
Ä
Save the configuration of the switching outputs in the device.
Click on the
icon.
BPS 3xx
i
SM 100 D
Fig. 9.6:
Configuration of the switching outputs
Possible signals via the switching outputs:
• Position limit 1/2
Signals a value above/below the position limit.