Technical data
Leuze electronic GmbH + Co. KG
BPS 307i
78
Tab. 13.6:
Certifications, conformity
Conformity
CE, CDRH
Certifications
UL 60950-1, CSA C 22.2 No. 60950-1
CAUTION
UL applications!
For UL applications, use is only permitted in Class 2 circuits in accordance with the NEC (Na-
tional Electric Code).
13.1.1 BPS without heating
CAUTION
UL applications!
For UL applications, use is only permitted in Class 2 circuits in accordance with the NEC (Na-
tional Electric Code).
Tab. 13.7:
Electrical equipment
Data specification
Values/description
Interface type
SSI
SSI clock rate (CLOCK): 50 kHz … 800 kHz
Service USB interface
Mini-B type USB 2.0 socket
PWR LED green
Device ready (power on)
Operating voltage U
B
18 … 30 VDC (Class 2, protection class III)
Power consumption
Max. 3.7 W
Tab. 13.8:
Ambient temperature
Ambient temperature (operation)
-5 °C … +50 °C
Ambient temperature (storage)
-35 °C … +70 °C