NOTICE
A twin tape always consists of two bar code tapes.
Ä
When ordering twin tapes, two bar code tapes are always included with an order.
Ä
The two twin bar code tapes have the exact same length tolerances relative to each other.
Ä
Ensure that the BCB is affixed without tension.
The BCB is a plastic tape that can be stretched by strong mechanical tension. Excessive
mechanical stretching results in lengthening of the tape and distortion of the position values.
Mounting two bar code tapes with the same value range
For crane systems or elevators, two bar code tapes with the same value range are used for positioning.
NOTICE
If two bar code tapes with the same value range and the same length tolerances are needed,
the use of twin tapes is recommended (see chapter 3.4.4 "Twin tapes").
If a twin tape is not used: To have the same values at the same position, one bar code tape must be affixed
with numbers upside down while the other is affixed normally.
If twin bar code tapes are not used, the two bar code tapes may d/- 1 mm per meter relative to one
another.
1
2
1
BCB affixed upside down
2
BCB affixed normally
Fig. 6.7:
Affixing two bar code tapes with the same value range
6.2
Mounting the bar code positioning system
The BPS can be mounted in the following ways:
• Mounting using a mounting device on the fastening grooves
• BTU 0300M-W: Wall mounting
• BT 56: Mounting on a rod
• Mounting using a mounting device on the M4 mounting threads on the rear of the device
• BT 300 W: Mounting on a mounting bracket
• BT 300-1: Mounting on a rod
• Mounting using four M4 mounting threads on the rear of the device
NOTICE
If the BTU 0300M-W mounting device is used to mount the device, the new device is automati-
cally aligned correctly should it be necessary to exchange a device.