If the output is deactivated via the switch-off signal before the start-up delay lapses, only a brief pulse
appears at the output following the start-up delay.
• Debounce time
Parameter for setting the software debounce time for the switching input. The definition of a debounce
time extends the signal transition time accordingly.
If this parameter has the value
0
, no debouncing takes place. Otherwise, the set value corresponds to
the time (in ms) that the input signal must be present and stable.
• Switch-off delay
This parameter specifies the duration of the switch-off delay (in ms).
Configuration of the resolution for position and speed measurement on the SSI interface (
OUTPUT
tab, Preparation > SSI)
Fig. 9.8:
webConfig function
OUTPUT > Preparation > SSI
• Position resolution
Resolution for the position value
• Speed resolution
Resolution for the speed value
Configuration of the bar code tape selection and tape value correction (
MEASUREMENT DATA
tab,
Bar code tape)
• Bar code tape with 30 mm grid (BCB G30 …) or 40 mm grid (BCB G40 …)
• Tape value correction
With this parameter, the deviation of the BCB from the correct millimeter scaling that arises from the
production process can be corrected.
Configuration of position detection (
DATA PROCESSING
tab, Position > Detection)
• Integration depth
Number of successive measurements that the BPS uses for position determination.
• Scaling free resolution
Free scaling of the output of the position values.
• Preset
A preset position value (preset value) is activated at an appropriate position.
• Offset
Output value=measurement value+offset