Leuze electronic
BCL 558
i
93
TNT
35/7-2
4
V
Decoder table
In the
Decoder table
submenu, 4 different code type definitions can be stored. Bar codes
that have been read can only be decoded if they correspond to one of the definitions stored
here.
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Max. no. of
labels
Value between 0 and 64
The value set here specifies the maximum
number of labels that should be detected for
each reading gate.
1
Decoder 1
Symbology
(Code type)
No code
Code 2 of 5 interleaved
Code 39
Code 32
Code UPC
Code EAN
Code 128
EAN Addendum
Codabar
Code 93
GS1 DataBar Omnidirectional
GS1 DataBar Limited
GS1 DataBar Expanded
If
No code
is configured, the current and
all subsequent decoders are deactivated.
Code 2/5i
Number of digits
Interval mode
OFF/ON
With the
ON
setting, the values in digits 1
and 2 define a range of character numbers
that are to be read.
OFF
Digits 1
0 to 64 characters
First decodable number of characters or
lower range limit.
10
Digits 2
0 to 64 characters
Second decodable number of characters or
upper range limit.
0
Digits 3
0 to 64 characters
Third decodable number of characters.
0
Digits 4
0 to 64 characters
Fourth decodable number of characters.
0
Digits 5
0 to 64 characters
Fifth decodable number of characters.
0
Reading reliability
Value from 2 to 100
Number or scans required to reliably detect
a label.
4
Table 8.2:
Decoder table submenu