Notice!
Toggle bits are control and monitoring control flags which are not level-sensitive, but rather
triggered by edges.
Attributes 1-4
Attributes 1-4 are not supported in this profile.
Status (input/output)
Signal state of switching input or output.
Output activation
Sets the state of the switching output.
0
Switching output
0 - low - inactive
1
Switching output
1 - high - active
Reset Event Counter
Resets the event counter of the activation function back to zero.
0
1
perform reset
1
0
no function
Switching output comparative state (event counter)
Indicates whether the event counter has exceeded the set comparative value.
The bit is reset to the init. value by resetting the event counter.
0
not exceeded
1
exceeded
Switching output comparative state toggle bit (event counter)
If
SWOUT switches several times
was configured as comparison mode, this bit is toggled
each time the event counter is exceeded. The bit is reset to the init. value by resetting the
event counter.
0
1
event counter exceeded
1
0
event counter exceeded again