Display and control panel
8.1
Structure of the control panel
Figure 8.1:
Structure of the control panel
8.2
Status display and operation
8.2.1
Indicators in the display
Status displays of the switching inputs/outputs
IO1
Switching input or switching output 1 active (function dependent on set configuration).
Default: Switching input with the "Reading gate activation" function
IO2
Switching input or switching output 2 active (function dependent on set configuration).
Default: Input with the "Teach-in" function
IO3
Switching input or switching output 3 active (function dependent on set configuration).
Default: Switching input with the "Reading gate activation" function
IO4
Switching input or switching output 4 active (function dependent on set configuration).
Default: Switching output with the "No read" function
ATT
Warning (Attention)
ERR
Internal device error (Error) -> The device must be sent in for inspection
Bar graph
The read quality is described on a scale of 0 - 100%. The quality is evaluated based on the
"Equal Scans" of the read result configured in the bar code reader.
NET
IO1 IO2 IO3
IO4 ATT ERR
USB
MS
12345678
ENIP
LED
LED
Control buttons
Read result
Bar graph
Status display
EtherNet/IP status
USB interface