Leuze electronic
BCL 558
i
141
TNT
35/7-2
4
V
Structure of input assembly 102
Structure of output assembly 120
Structure of configuration assembly 190
Since the configuration is not used, the length of the configuration assembly is specified
as 0. The device then operates with the default values. In this case, the acknowledge mode
is not used.
Below, examples of what data exchange looks like during two subsequent activations are
shown. Switching output 1 reflects the activation signal. Switching output 2 displays whether
the result is valid (status input/output I/O 2 = 1] or whether a NoRead has taken place (status
input/output
I/O 2 = 0).
Inst.
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
102
0
Device status
1
Reserved
Switching
output com-
parison state
2
(toggle bit)
Switching
output com-
parison state
2
Status
input/output
I/O
2
Reserved
Switching
output com-
parison state
1
(toggle bit)
Switching
output com-
parison state
1
Status
input/output
I/O
1
2
Reserved
Switching
output com-
parison state
4
(toggle bit)
Switching
output com-
parison state
4
Status
input/output
I/O
4
Reserved
Switching
output com-
parison state
3
(toggle bit)
Switching
output com-
parison state
3
Status
input/output
I/O
3
3
Reserved
Error code
Reserved
Data rejec-
tion
(toggle bit)
Data accep-
tance
(toggle bit)
4
Fragment number (see chapter 10.7.5 "Class 107 - Result data")
5
Remaining fragments (see chapter 10.7.5 "Class 107 - Result data")
6
Fragment size (see chapter 10.7.5 "Class 107 - Result data")
7
Number of results
8
Reserved
Waiting for
acknowl-
edgement
New result
(toggle bit)
Buffer
overflow
Further
results in the
buffer
User data or
command
Status
activation
9
Result data length (low byte)
10
Result data length (high byte)
11
Data byte 0
12
Data byte 1
…
…
21
Data byte 10
Inst.
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
120
0
Reserved
Standby
Error
acknowledge
Data reset
Data
acknowl-
edgement
Activation
signal
1
Reset event
counter
4
Activation
switching
output
4
1)
1)
To be able to use the
Activation switching output
function, the output function must be
set to
External event
in webConfig.
Reset event
counter
3
Activation
switching
output
3
1)
Reset event
counter
2
Activation
switching
output
2
1)
Reset event
counter
1
Activation
switching
output
1
1)