88
BCL 558
i
Leuze electronic
NET LED
off
No supply voltage
- no communication possible
- no IP address assigned
flashes green
Initialization
- self test running
- no EtherNet/IP communication present
- BCL 558
i
is not assigned to any master
green continuous light Operation ok
- BCL 558
i
bus communication ok
flashes red
Communication error
- self test running
- time-out in bus communication
red continuous light
Network error
- double IP address
green/red flashing
Self test
- self test running
8.2.3
Control buttons
Up
Navigate upward/laterally.
Down
Navigate downward/laterally.
ESC
Exit menu item.
ENTER
Confirm/enter value, change menu levels.
Navigating within the menus
The menus within a level are selected with the up/down buttons
.
The selected menu item is activated with the enter button
.
Press the ESC button
to move up one menu level.
When one of the buttons is actuated, the display illumination is activated for 10min.
ESC
ESC