126
BCL 558
i
Leuze electronic
10.7.3
Class 103 - I/O status and control
This class is for handling switching input and switching output signals.
Object class 103 = 0x67
Services:
• Get attribute single 0x0E
• Set attribute single 0x10
Path
Designation
Size
in bit
Data type
Default
(dec)
Min
(dec)
Max
(dec)
Access
Cl.
Inst.
Attr.
103
1
1-4
Reserved
SWIO_1
5
Status (input/output)
8
U8
0
0
1
Get
6
Output activation
8
U8
0
0
1
Set
7
Reset Event Counter
8
U8
0
0
1
Set
8
Switching output
comparative state
(event counter)
8
U8
0
0
1
Get
9
Switching output
comparative state
toggle bit (event
counter)
8
U8
0
0
1
Get
103
2
1-4
Reserved
SWIO_2
5
Status (input/output)
8
U8
0
0
1
Get
6
Output activation
8
U8
0
0
1
Set
7
Reset Event Counter
8
U8
0
0
1
Set
8
Switching output
comparative state
(event counter)
8
U8
0
0
1
Get
9
Switching output
comparative state
toggle bit (event
counter)
8
U8
0
0
1
Get
103
3
1-4
Reserved
SWIO_3
5
Status (input/output)
8
U8
0
0
1
Get
6
Output activation
8
U8
0
0
1
Set
7
Reset Event Counter
8
U8
0
0
1
Set
8
Switching output
comparative state
(event counter)
8
U8
0
0
1
Get
9
Switching output
comparative state
toggle bit (event
counter)
8
U8
0
0
1
Get
103
4
1-4
Reserved
SWIO_4
5
Status (input/output)
8
U8
0
0
1
Get
6
Output activation
8
U8
0
0
1
Set
7
Reset Event Counter
8
U8
0
0
1
Set
8
Switching output
comparative state
(event counter)
8
U8
0
0
1
Get
9
Switching output
comparative state
toggle bit (event
counter)
8
U8
0
0
1
Get