120
BCL 558
i
Leuze electronic
Input assembly instance 101
Instance 101, attribute 3
Input assembly, length
min. 1 byte
max. 264 bytes
The number of data starting at byte 9 is defined in the control while configuring the BCL 558
i
.
This makes it possible to use the assembly with any length.
Notice!
The use of the assembly is illustrated with examples at the end of this chapter.
Notice!
Formula for calculating the assembly length:
Length of the assembly = 9 + length of the result/bar code
For results/bar codes with length
10
, the assembly must be configured with a length of
9 + 10 = 19
.
Inst.
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
101
0
Device status
1
Reserved
Error code
Reserved
Data
rejection
(toggle bit)
Data
acceptance
(toggle bit)
2
Fragment number (see chapter 10.7.5 "Class 107 - Result data")
3
Remaining fragments (see chapter 10.7.5 "Class 107 - Result data")
4
Fragment size (see chapter 10.7.5 "Class 107 - Result data")
5
Number of results
6
Reserved
Waiting for
acknowl-
edgement
New result
(toggle bit)
Buffer
overflow
Further
results in the
buffer
User data or
command
Status
activation
7
Result data length (low byte)
8
Result data length (high byte)
9
Data byte 0
10
Data byte 1
…
…
263
Data byte 254