154
BCL 558
i
Leuze electronic
The configuration is now transferred to the external parameter memory and is from now on
updated immediately when the configuration is changed via display or online commands.
Replacing a defective BCL 558
i
Uninstall the defective BCL 558
i
.
Remove the screw cap of the USB connection of the defective BCL 558
i
and remove the
external parameter memory.
Mount the external parameter memory and the screw cap onto the new BCL 558
i
.
Install and commission the new BCL 558
i
.
The following message appears on the display again:
Attention!
Make sure you select Cancel
.
Otherwise, the configuration in the external parameter memory
is lost!
The configuration is now imported from the external parameter memory and the BCL 558
i
is immediately operational without any further configuration.
MS
The display of
MS
under the Link state indicates that the
USB memory stick is connected correctly and is function-
ing.
ENIP
Memory stick connected:
Export internal
configuration?
OK
cancel.
Use the arrow keys
to select Cancel and then press
the enter button
.