156
BCL 558
i
Leuze electronic
11.1.1
General 'online' commands
Software version number
Notice!
This command returns the major release number of the software packet. This major release
number also appears on the display during start-up.
This command can be used to check whether the connected host or service computer is
properly connected and configured. If you do not receive an acknowledgement, please
check interface connections, protocol and service switches.
Software reset
Command
’V’
Description
Requests device version information
Parameter
No
Acknowledgment
'BCL 558i SM 100 V 1.2.3 2013-05-15'
The first line contains the device type of the BCL 558
i
, followed by the device version
number and version date. (The data which is actually displayed may vary from the
values given here)
Command
’H’
Description
Carries out a software reset. The device is restarted and reinit.ialized, leaving it in the
same state as when the supply voltage is switched on.
Parameter
No
Acknowledgment
’S’
(start signal)