149
TNT
35/7-2
4
V
10.9
Additional settings for the BCL 558
i
After the basic configuration of the operating mode and the communication parameters, you
need to carry out further settings:
• Decoding and processing the read data
• Control of the decoding
• Control of the switching outputs
10.9.1
Decoding and processing the read data
The BCL 558
i
offers the following options:
• Setting the number of labels to be decoded for each reading gate (0 … 64). This is
done via the
Max. no. of labels
parameter.
• Definition of up to 8 different code types (4 different types if configured via the dis-
play). Labels that match one of the defined code types are decoded. Further parame-
ters can be set for each code type:
•
The code type (
symbology
)
•
The
Number of digits
: either up to 5 different numbers of digits (e.g., 10, 12, 16,
20, 24), or a range (
Interval mode
) and up to three additional numbers of digits
(e.g., 2 … 10, 12, 16, 26)
•
The
Reading reliability
: the set value specifies how many times a label must
be read and decoded with the same result before the result is accepted as valid.
•
Activation of the code fragment technology (
CRT
, in the webConfig tool only)
•
Additional code type specific settings (in the webConfig tool only)
•
Check digit method
used for decoding as well as the type of
Check digit
output
for the read result. The two possibilities for the latter are
Standard
(corre-
sponds to the standard for the selected code type/symbology) and not
Standard
.
Define at least one code type with the desired settings.
• via webConfig:
Configuration -> Decoder
• or, alternatively, via the display
Parameter -> Decoder table