Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 8, “Parts Listing, TD200x Machine Types 3719, 3821, 3822, and 3823,” on page 237 to
determine which components are customer replaceable units (CRU) and which components are field
replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
00580A4
Memory population changed
Information only. Memory has been added, moved, or
changed.
00580A5
Mirror failover complete
Information only. Memory redundancy has been lost.
Check the event log for uncorrected DIMM failure
events.
0068002
CMOS battery cleared
1. Reseat the battery.
2. Clear the CMOS memory (see “System-board
switches and jumpers” on page 144).
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. (Trained service technician only) System
board
2011000
PCI-X PERR
1. Check the extender card LEDs.
2. Reseat all affected adapters and extender cards.
3. Update the PCI device firmware.
4. Remove the adapters from the extender card.
5. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Extender card
b. (Trained service technician only) System
board
2011001
PCI-X SERR
1. Check the extender-card LEDs.
2. Reseat all affected adapters and extender cards.
3. Update the PCI device firmware.
4. Remove the adapters from the extender card.
5. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Extender card
b. (Trained service technician only) System
board
Chapter 5. Diagnostics
33
Содержание THINKSERVER 3719
Страница 1: ...ThinkServer TD200x Machine Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 2: ......
Страница 3: ...ThinkServer TD200x Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 12: ...4 ThinkServer TD200x Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 22: ...14 ThinkServer TD200x Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 28: ...20 ThinkServer TD200x Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 34: ...26 ThinkServer TD200x Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 244: ...236 ThinkServer TD200x Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 258: ...250 ThinkServer TD200x Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 282: ...274 ThinkServer TD200x Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 286: ...278 ThinkServer TD200x Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 296: ...288 ThinkServer TD200x Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 303: ......
Страница 304: ...Part Number XXXXXX Printed in USA 1P P N XXXXXX ...