5. Remove the power supply or power supplies from the power-supply cage (see
“Removing a hot-swap power supply” on page 174).
6. Rotate the power-supply cage to its open position (see “Opening the
power-supply cage” on page 158).
7. Remove the air baffle (see “Removing the air baffle” on page 169).
8. Remove the microprocessor heat sink:
a. Lift the heat-sink release lever to the fully open position.
b. Rotate the back of the heat sink out of the retention bracket and remove
the heat sink from the server.
Attention:
Do not touch the thermal grease on the bottom of the heat
sink. Touching the thermal grease will contaminate it. If the thermal grease
on the microprocessor or heat sink becomes contaminated, you must
replace it. See “Thermal grease” on page 226 for more information.
1
Heat sink flange
2
Microprocessor
3
Release level locking tab
4
Retainer bracket
5
Alignment tab
6
Heat sink release level
7
Notch
9. Lift the microprocessor-release latch to the fully open position (approximately
135° angle); then, lift the bracket frame and remove the microprocessor from
the socket.
Chapter 7. Installing optional devices and replacing customer replaceable units
219
Содержание THINKSERVER 3719
Страница 1: ...ThinkServer TD200x Machine Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 2: ......
Страница 3: ...ThinkServer TD200x Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 12: ...4 ThinkServer TD200x Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 22: ...14 ThinkServer TD200x Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 28: ...20 ThinkServer TD200x Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 34: ...26 ThinkServer TD200x Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 244: ...236 ThinkServer TD200x Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 258: ...250 ThinkServer TD200x Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 282: ...274 ThinkServer TD200x Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 286: ...278 ThinkServer TD200x Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 296: ...288 ThinkServer TD200x Types 3719 3821 3822 and 3823 Hardware Maintenance Manual ...
Страница 303: ......
Страница 304: ...Part Number XXXXXX Printed in USA 1P P N XXXXXX ...