Diagnostic Error Code
FRU/Action
170-196-XXX
Voltage Sensor(s) test halt, error threshold
exceeded
1.
Press F3 to review the log file
2. Re-start the test to reset the log file
170-197-XXX
Voltage Sensor(s) test warning
1.
Make sure the component that is called out
is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 37
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
170-198-XXX
Voltage Sensor(s) test aborted
1.
If a component is called out, make sure it is
connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 37
2. Flash the system and re-test. See “Flash update
procedures” on page 179
3. Go to “Undetermined problems” on page 63
170-199-XXX
Voltage Sensor(s) test failed, cause
unknown
1.
See “Undetermined problems” on page 63
2. Flash the system and re-test. See “Flash update
procedures” on page 179
3. Replace component under function test
170-250-XXX 170-251-XXX
Voltage Sensor(s) Voltage
limit error
1.
Power supply
2. System board
170-254-XXX
Voltage Sensor(s) Voltage Regulator
Module error
1.
Voltage Regulator Module (VRM)
2. Microprocessor
3. System board
175-000-XXX
Thermal Sensor(s) Test Passed
No action
175-0XX-XXX
Thermal Sensor(s) failure
1.
Flash system
2. System board
175-195-XXX
Thermal Sensor(s) Test aborted by user
Information only
Re-start the test, if necessary
175-196-XXX
Thermal Sensor(s) test halt, error threshold
exceeded
1.
Press F3 to review the log file
2. Re-start the test to reset the log file
175-197-XXX
Thermal Sensor(s) test warning
1.
Make sure the component that is called out
is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 37
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
175-198-XXX
Thermal Sensor(s) test aborted
1.
If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test. See “Flash update
procedures” on page 179
3. Go to “Undetermined problems” on page 63
Chapter 7
.
Symptom-to-FRU Index
57
Содержание ThinkCentre A70z ALL-IN-ONE
Страница 1: ...ThinkCentre Hardware Maintenance Manual Machine Types 0401 0421 0994 1165 1184 1186 and 2565 ...
Страница 2: ......
Страница 3: ...ThinkCentre Hardware Maintenance Manual Machine Types 0401 0421 0994 1165 1184 1186 and 2565 ...
Страница 15: ...Chapter 2 Safety information 9 ...
Страница 16: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 10 ThinkCentre Hardware Maintenance Manual ...
Страница 19: ...Chapter 2 Safety information 13 ...
Страница 20: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Страница 21: ...Chapter 2 Safety information 15 ...
Страница 27: ...Chapter 2 Safety information 21 ...
Страница 31: ...Chapter 2 Safety information 25 ...
Страница 46: ...40 ThinkCentre Hardware Maintenance Manual ...
Страница 188: ...182 ThinkCentre Hardware Maintenance Manual ...
Страница 192: ...186 ThinkCentre Hardware Maintenance Manual ...
Страница 193: ......
Страница 194: ...Part Number 71Y7087 Printed in USA 1P P N 71Y7087 71Y7087 ...