Diagnostic Error Code
FRU/Action
018-199-XXX
PCI Card test failed, cause unknown
1. Go to “Undetermined problems” on page 63
2. Flash the system and re-test. See “Flash update
procedures” on page 179
3. Replace component under function test
018-250-XXX
PCI Card Services error
1.
PCI card
2. Riser card, if installed
3. System board
020-000-XXX
PCI Interface Test Passed
No action
020-0XX-XXX
PCI Interface error
1.
PCI card
2. Riser card, if installed
3. System board
020-195-XXX
PCI Test aborted by user
Information only
Re-start the test, if necessary
020-196-XXX
PCI test halt, error threshold exceeded
1.
Press F3 to review the log file
2. Re-start the test to reset the log file
020-197-XXX
PCI test warning
1.
Make sure the component that is called out
is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 37
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
020-198-XXX
PCI test aborted
1.
If a component is called out, make sure it is
connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 37
2. Flash the system and re-test. See “Flash update
procedures” on page 179
3. Go to “Undetermined problems” on page 63
020-199-XXX
PCI test failed, cause unknown
1. Go to “Undetermined problems” on page 63
2. Flash the system and re-test. See “Flash update
procedures” on page 179
3. Replace component under function test
020-262-XXX
PCI system error
1.
PCI card
2. Riser card, if installed
3. System board
025-000-XXX
IDE interface Test Passed
No action
025-00X-XXX 025-01X-XXX
IDE interface failure
1.
IDE signal cable
2. Check power supply voltages
3. Reseat IDE signal cable
4. IDE device
5. System board
Chapter 7
.
Symptom-to-FRU Index
51
Содержание ThinkCentre A70z ALL-IN-ONE
Страница 1: ...ThinkCentre Hardware Maintenance Manual Machine Types 0401 0421 0994 1165 1184 1186 and 2565 ...
Страница 2: ......
Страница 3: ...ThinkCentre Hardware Maintenance Manual Machine Types 0401 0421 0994 1165 1184 1186 and 2565 ...
Страница 15: ...Chapter 2 Safety information 9 ...
Страница 16: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 10 ThinkCentre Hardware Maintenance Manual ...
Страница 19: ...Chapter 2 Safety information 13 ...
Страница 20: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Страница 21: ...Chapter 2 Safety information 15 ...
Страница 27: ...Chapter 2 Safety information 21 ...
Страница 31: ...Chapter 2 Safety information 25 ...
Страница 46: ...40 ThinkCentre Hardware Maintenance Manual ...
Страница 188: ...182 ThinkCentre Hardware Maintenance Manual ...
Страница 192: ...186 ThinkCentre Hardware Maintenance Manual ...
Страница 193: ......
Страница 194: ...Part Number 71Y7087 Printed in USA 1P P N 71Y7087 71Y7087 ...