Table 2. Events organized by severity (continued)
Event ID
Message String
Severity
FQXSPUN2019I
Sensor [SensorElementName] has transitioned to a less severe state
from critical.
Informational
FQXSPUN2020I
Sensor [SensorElementName] has deasserted the transition to non-
recoverable from a less severe state.
Informational
FQXSPUN2023I
Sensor [SensorElementName] has deasserted the transition to non-
recoverable.
Informational
FQXSPUN2050I
The RAID controller in PCI slot [arg1] is no longer in critical status.
Informational
FQXSPUN2057I
The RAID controller in PCI slot [arg1] has a battery now.
Informational
FQXSPUP0002I
A firmware or software change occurred on system
[ComputerSystemElementName].
Informational
FQXSPUP4001I
Flash of [arg1] from [arg2] succeeded for user [arg3] .
Informational
FQXSPUP4002I
Flash of [arg1] from [arg2] failed for user [arg3].
Informational
FQXSPUP4006I
Auto promote primary XCC to backup is [arg1] by user [arg2] from
[arg3] at IP address [arg4].
Informational
FQXSPWD0000I
Watchdog Timer expired for [WatchdogElementName].
Informational
FQXSPWD0001I
Reboot of system [ComputerSystemElementName] initiated by
watchdog [WatchdogElementName].
Informational
FQXSPWD0002I
Powering off system [ComputerSystemElementName] initiated by
watchdog [WatchdogElementName].
Informational
FQXSPWD0003I
Power cycle of system [ComputerSystemElementName] initiated by
watchdog [WatchdogElementName].
Informational
FQXSPWD0004I
Watchdog Timer interrupt occurred for [WatchdogElementName].
Informational
FQXSPBR4001I
Running the backup Management Controller [arg1] main application.
Warning
FQXSPCA0007J
Numeric sensor [NumericSensorElementName] going high (upper
non-critical) has asserted.
Warning
FQXSPDM4002I
Device [arg1] VPD is not valid.
Warning
FQXSPEA0001J
Sensor [SensorElementName] has transitioned from normal to non-
critical state.
Warning
FQXSPIO0014J
Bus [SensorElementName] is operating in a degraded state.
Warning
FQXSPMA0010J
[PhysicalMemoryElementName] on Subsystem
[MemoryElementName] Throttled.
Warning
FQXSPNM4010I
DHCP[[arg1]] failure, no IP address assigned.
Warning
FQXSPNM4032I
DHCPv6 failure, no IP address assigned.
Warning
FQXSPPP4009I
The measured power value exceeded the power cap value.
Warning
FQXSPPP4010I
The new minimum power cap value exceeded the power cap value.
Warning
FQXSPPU0002G
The Processor [ProcessorElementName] is operating in a Degraded
State.
Warning
FQXSPPW0003G
Failure predicted on [PowerSupplyElementName].
Warning
FQXSPPW0006I
[PowerSupplyElementName] has lost input.
Warning
19
Содержание 7Z70
Страница 1: ...ThinkSystem SR630 V2 Messages and Codes Reference Machine Types 7Z70 and 7Z71 ...
Страница 4: ...ii ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 6: ...2 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 204: ...200 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 208: ...204 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 210: ...206 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 211: ......
Страница 212: ......