Complete the following steps until the problem is solved:
1. Check Lenovo Support (http://support.lenovo.com/) for service bulletins, Tech tips, and firmware
update related to your drive.
2. Check for any other RAID-related error.
3. Replace the drive.
•
FQXSPSD0003G: Failure Predicted on drive [arg1] in the enclosure/chassis (MTM-SN: [arg2]).
This message is for the use case when an implementation has detected an Array Failure is Predicted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: System - Predicted Failure
SNMP Trap ID: 27
CIM Prefix: PLAT CIM ID: 0168
User Action:
Complete the following steps until the problem is solved:
1. Check if there is any drive failure.
2. If yes, replace the failed drive.
3. If the problem persists, collect service data log from the XCC WebGUI and contact Lenovo Support.
•
FQXSPSD0003I: Hot Spare enabled for [ComputerSystemElementName].
This message is for the use case when an implementation has detected a Hot Spare has been Enabled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0170
User Action:
Information only; no action is required.
•
FQXSPSD0005I: Hot Spare enabled for drive [arg1] in the enclosure/chassis (MTM-SN: [arg2]).
This message is for the use case when an implementation has detected a Hot Spare has been Enabled.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0170
User Action:
Information only; no action is required.
•
FQXSPSD0005L: Array [ComputerSystemElementName] is in critical condition.
This message is for the use case when an implementation has detected that an Array is Critical.
Severity: Error
Serviceable: Yes
98
ThinkSystem SR630 V2 Messages and Codes Reference
Содержание 7Z70
Страница 1: ...ThinkSystem SR630 V2 Messages and Codes Reference Machine Types 7Z70 and 7Z71 ...
Страница 4: ...ii ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 6: ...2 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 204: ...200 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 208: ...204 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 210: ...206 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 211: ......
Страница 212: ......