
Note:
Some cluster solutions require specific code levels or coordinated code updates. If the device
is part of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
3. If problem persists, collect Service Data log.
4. Contact Lenovo Support.
•
FQXSPUP4004I: XCC firmware mismatch between nodes/servers [arg1] and [arg2]. Please attempt
to flash the XCC firmware to the same level on all nodes/servers.
A mismatch of XCC firmware has been detected between nodes/servers
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0132
User Action:
Complete the following steps until the problem is solved:
1. Reflash XCC/BMC firmware to the latest version on all servers.
Note:
Some cluster solutions require specific code levels or coordinated code updates. If the device
is part of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
2. If problem persists, collect Service Data log.
3. Contact Lenovo Support.
•
FQXSPUP4005I: FPGA firmware mismatch between nodes/servers [arg1] and [arg2]. Please
attempt to flash the FPGA firmware to the same level on all nodes/servers.
A mismatch of FPGA firmware has been detected between nodes/servers
Severity: Error
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID: 22
CIM Prefix: IMM CIM ID: 0133
User Action:
Complete the following steps until the problem is solved:
1. Reflash XCC/BMC firmware to the latest version on all servers.
Note:
Some cluster solutions require specific code levels or coordinated code updates. If the device
is part of a cluster solution, verify that the latest level of code is supported for the cluster solution
before you update the code.
2. If problem persists, collect Service Data log.
3. Contact Lenovo Support.
•
FQXSPUP4006I: Auto promote primary XCC to backup is [arg1] by user [arg2] from [arg3] at IP
address [arg4].
Auto promote primary XCC to backup is enabled or disabled.
Severity: Info
132
ThinkSystem SR630 V2 Messages and Codes Reference
Содержание 7Z70
Страница 1: ...ThinkSystem SR630 V2 Messages and Codes Reference Machine Types 7Z70 and 7Z71 ...
Страница 4: ...ii ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 6: ...2 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 204: ...200 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 208: ...204 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 210: ...206 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 211: ......
Страница 212: ......