Information only; no action is required.
•
FQXSPPU2007I: The System [ComputerSystemElementName] has detected a POST Error
deassertion.
This message is for the use case when an implementation has detected that Post Error has deasserted.
Severity: Info
Serviceable: Yes
Automatically notify Support: No
Alert Category: Critical - CPU
SNMP Trap ID: 40
CIM Prefix: PLAT CIM ID: 0185
User Action:
Information only; no action is required.
•
FQXSPPW0001I: [PowerSupplyElementName] has been added to container
[PhysicalPackageElementName].
This message is for the use case when an implementation has detected a Power Supply has been added.
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: System - Other
SNMP Trap ID:
CIM Prefix: PLAT CIM ID: 0084
User Action:
Information only; no action is required.
•
FQXSPPW0002L: [PowerSupplyElementName] has Failed.
This message is for the use case when an implementation has detected a Power Supply has failed.
Severity: Error
Serviceable: Yes
Automatically notify Support: Yes
Alert Category: Critical - Power
SNMP Trap ID: 4
CIM Prefix: PLAT CIM ID: 0086
User Action:
Complete the following steps until the problem is solved:
1. Check the PSU LED:
a. If AC LED is not lit, check the power cord and input voltage.
b. If DC LED is not lit or fault LED is lit, remove and then reinstall the power supply.
2. If the problem persists, collect service data log from the XCC WebGUI and contact Lenovo Support.
•
FQXSPPW0003G: Failure predicted on [PowerSupplyElementName].
This message is for the use case when an implementation has detected a Power Supply failure is
predicted.
Severity: Warning
Serviceable: Yes
Automatically notify Support: No
85
Содержание 7Z70
Страница 1: ...ThinkSystem SR630 V2 Messages and Codes Reference Machine Types 7Z70 and 7Z71 ...
Страница 4: ...ii ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 6: ...2 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 204: ...200 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 208: ...204 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 210: ...206 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 211: ......
Страница 212: ......