Automatically notify Support: No
Alert Category: none
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0056
User Action:
Information only; no action is required.
•
FQXSPNM4030I: ENET[[arg1]] DHCPv6-HSTN=[arg2], DN=[arg3], IP@=[arg4], Pref=[arg5], DNS1@=
[arg5].
IPv6 DHCP-assigned address is active
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: none
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0057
User Action:
Information only; no action is required.
•
FQXSPNM4031I: IPv6 static address of network interface modified from [arg1] to [arg2] by user
[arg3].
A user modifies the IPv6 static address of a Management Controller
Severity: Info
Serviceable: No
Automatically notify Support: No
Alert Category: none
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0058
User Action:
Information only; no action is required.
•
FQXSPNM4032I: DHCPv6 failure, no IP address assigned.
S DHCP6 server fails to assign an IP address to a Management Controller.
Severity: Warning
Serviceable: No
Automatically notify Support: No
Alert Category: none
SNMP Trap ID:
CIM Prefix: IMM CIM ID: 0059
User Action:
Complete the following steps until the problem is solved:
1. Make sure that the XCC/BMC manegment network cable is connected and the network ports is
active.
2. Make sure that there is a DHCPv6 server on the network that can assign an IP address to the XCC/
BMC.
3. If problem persists, collect Service Data log.
61
Содержание 7Z70
Страница 1: ...ThinkSystem SR630 V2 Messages and Codes Reference Machine Types 7Z70 and 7Z71 ...
Страница 4: ...ii ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 6: ...2 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 204: ...200 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 208: ...204 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 210: ...206 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 211: ......
Страница 212: ......