User Action:
Information only; no action is required.
•
FQXPMSR0021L: Failed to create new virtual disk.
Severity: Warning
User Action:
1. Ensure LXPM and RAID adapter firmware are at the latest levels.
2. Ensure the state of RAID adapter and disk drives are both healty.
3. Verify proper physical connection of the disk drive, SAS expander (if applicable)and RAID adapter.
4. Ensure the drive status is correct (Unconfigured Good).
5. Reboot the machine and retry to create new virtual disk.
6. If the problem persists, please contact technical support.
•
FQXPMSR0022I: Create new virtual disk successfully.
Severity: Info
User Action:
Information only; no action is required.
•
FQXPMSR0031L: Failed to remove existing virtual disk
Severity: Warning
User Action:
1. Ensure LXPM and RAID adapter firmware are at the latest levels.
2. Ensure the state of RAID adapter and disk drives are both healty.
3. Verify proper physical connection of the disk drive, SAS expander (if applicable)and RAID adapter.
4. Reboot the machine and retry to remove the existing virtual disk.
5. If the problem persists, please contact technical support.
•
FQXPMSR0032I: Removed existing virtual disk successfully.
Severity: Info
User Action:
Information only; no action is required.
•
FQXPMUP0001K: The system configuration does not meet the prerequisite
Severity: Warning
User Action:
1. Follow prompts to update the firmware and retry the update.
2. If the problem persists, please contact technical support.
•
FQXPMUP0002K: The selected packages are not compatible
Severity: Warning
User Action:
1. Follow prompts to update each individual firmware package.
.
XClarity Provisioning Manager events
193
Содержание 7Z70
Страница 1: ...ThinkSystem SR630 V2 Messages and Codes Reference Machine Types 7Z70 and 7Z71 ...
Страница 4: ...ii ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 6: ...2 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 204: ...200 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 208: ...204 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 210: ...206 ThinkSystem SR630 V2 Messages and Codes Reference ...
Страница 211: ......
Страница 212: ......