3
IMPORTANT SAFETY INSTRUCTIONS
•
The dispenser is for indoor use only
•
This appliance is intended to be used in commercial
applications such as restaurants or similar.
•
This appliance is to be installed in a location where its use
can be overseen by trained personnel.
•
This appliance should not be used by children or infirm
persons without supervision.
•
This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction
concerning use of the appliance by a person responsible
for their safety.
•
This appliance can be used by children aged from 8 years
and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction
concerning use of the appliance in a safe way and
understand the hazards involved.
•
Cleaning and user maintenance shall not be performed by
children without supervision.
•
This unit is not a toy and children should be advised not to
play with the appliance.
•
The min/max ambient operating temperature for the
dispenser is
40°F to 90°F
(
4°C to 32°C
).
•
Do not operate unit below minimum ambient operation
conditions.
•
Should freezing occur, cease operation of the unit and
contact authorized service technician.
•
The maximum tilt for safe operation is 5°.
•
This appliance must be installed and serviced by a
professional.
!
Intended Use
•
Follow all local electrical codes when making connections.
•
Appliance must be supplied by 24 VDC.
•
Check dispenser name plate label, located inside tower
panels, for correct electrical requirements of unit.
DO NOT
plug into a wall electrical outlet unless the current shown
on the serial number plate agrees with local current
available.
•
Each dispenser must have a separate electrical circuit.
•
DO NOT
use extension cords with this unit.
•
DO NOT
‘gang’ together with other electrical devices on
the same outlet.
• WARNING:
Always disconnect electrical power to the unit
to prevent personal injury before attempting any internal
maintenance.
•
The resettable breaker switch should not be used as a
substitute for unplugging the dispenser from the power
source to service the unit.
•
Only qualified personnel should service internal
components of electrical control housing.
• WARNING:
Make sure that all water lines are tight and units
are dry before making any electrical connections
•
If this dispenser is installed in an area that is susceptible
to ±10% variation of the nominal line voltage, consider
installing a surge protector or similar protection device.
F
Power
• WARNING:
Carbon Dioxide (CO
2
) is a colorless,
noncombustible gas with a light pungent odor. High
percentages of CO
2
may displace oxygen in the blood.
• WARNING:
Prolonged exposure to CO
2
can be harmful.
Personnel exposed to high concentrations of CO
2
gas
will experience tremors which are followed by a loss of
consciousness and suffocation.
• WARNING:
If a CO
2
gas leak is suspected, immediately
ventilate the contaminated area before attempting to repair
the leak.
• WARNING:
Strict attention must be observed in the
prevention of CO
2
gas leaks in the entire CO
2
and soft
drink system.
5
Carbon Dioxide (CO
2
)
•
Appliance is not suitable for installation where a water jet
could be used.
•
Provide an adequate, potable water supply. Water pipe
connections and fixtures directly connected to a potable
water supply must be sized, installed, and maintained
according to federal, state, and local codes.
•
The water supply line must be at least a 9.525 mm (3/8
inches) pipe with a minimum of 20 psi (0.137 MPa) line
pressure, but not exceeding a maximum of 65 PSI (0.448
MPa). Water pressure exceeding 65 PSI (0.448 MPa)
must be reduced to 65 PSI (0.448 MPa).
•
Use a filter in the water line to avoid equipment damage
and beverage off-taste. Check the water filter periodically,
as required by local conditions.
• CAUTION:
The water supply must be protected by means
of an air gap, a backflow prevention device (located
upstream of the CO
2
injection system) or another
approved method to comply with NSF standards. A leaking
inlet water check valve will allow carbonated water to flow
back through the pump when it is shut off and contaminate
the water supply.
• CAUTION:
Ensure the backflow prevention device complies
with ASSE and local standards. It is the responsibility of
the installer to ensure compliance.
!
Water Notice