Dispenser/Chiller Installation
7
A. Mounting Plate
B. Counter Cutout
C. Counter Edge
A
B
C
1. Carefully lift unit and using a screwdriver, seperate the
mounting plate from the tower and drip tray.
2.
Remove the drain fitting from the drip tray. First, unscrew
the lower section then press firmly from the bottom to
remove the upper portion of the drain fitting.
3.
Using the six (6) mounting screws provided, secure the
mounting plate to the counter top.
When attaching the tower to the mounting plate, make
sure the screws do not extend more than 20 mm (0.78
inches) from the top of the mounting plate. These
could damage the valves when installing the
dispenser.
!
ATTENTION
E
A
B
C
A. Max. Height of 20 mm
B. Washer
C. Nut
D. Connecting Screw
E. Counter
D
4.
Using proper lifting techniques, lift the tower over the
counter top and slide the unit inlets and power cord through
the opening in the mounting plate/counter top.
5. Using the four (4) screws provided, connect/tighten tower to
mounting plate/counter top.
6.
Place gasket at the bottom of the drain then re-attach drain
fitting to drip tray, removed in Step 2.
A
C
E
F
G
D
B
A. Seal
B. Drip Tray
C. Mounting Plate
D. Counter
E. Upper Drain Fitting
F. Lower Drain Fitting
G. Washer
7. Install cup rest to drip tray.
8.
Route appropriate tubing from the recirculation chiller syrup
outlets to the syrup inlets on the tower. Connect tubing to
inlets using the oetiker pliers and fittings. Repeat for all
syrup connections.
9.
Route appropriate tubing from the recirculation chiller water
outlets to the carbonated/plain water inlets then connect
tubing to inlet. Repeat for all water connections including
the return inlet.
A
B
C
A. Oetiker Pliers
B. Fitting
C. Tubing
D. Syrup/Water
Inlet
D
10.
Route drain line from the designated floor drain to the drip
tray and connect drain line to drain nut installed in step 6.
NSF listed units must be sealed to the counter or have
four (4) inch legs installed.
NOTE