![lancer bridge tower Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/lancer/bridge-tower/bridge-tower_operation-manual_672754012.webp)
12
10.
Once a brand/flavor has been selected to a corresponding
module, press the Configuration button to return to the
Configuration Screen.
11.
Repeat steps 8 and 9 for any other desired brand or flavor
modules.
12.
Press the Menu button to return to the Service menu.
13.
From the Service Menu, press the Maintenance button.
14. Press the Purge tab on the far left side of the screen.
15.
Purge any new brand or flavor module until there is a
steady flow of product. (See page 11)
16. Press the Menu button to return to the Service Menu.
CALIBRATION AND MAINTENANCE
Calibrating Carbonated/Plain Water Modules
Finished drink flow rate = 44 ml/sec
Ratio = 5.4:1
44 ml/s X 5.4 / (5.4 + 1) = 37.13 ml/sec water flow rate
44 ml/s X 1 / (5.4 + 1) = 6.87 ml/sec syrup flow rate
EXAMPLE
A. Enter Flow Rate C. Start Purge Button
B. Timer Icon
D. Unit Icon
A
B
C
1.
From the Service menu, press the Maintenance button.
2. Press the Calibrate tab on the far left side of the screen and
press the Calibrate button for the carbonated water module.
3.
Enter the desired flow rate in milliliters per second (ml/sec).
This number is based on the target finished drink flow rate
of 44 ml/sec and the desired drink ratio.
D
A. Graduated Cylinder
B. Nozzle
A
B
4. Set the Timer to the ON position and select milliliters (ml) as
the desired unit of measurement.
5.
Using the keypad, enter a specific volume to be dispensed
based on the size of the graduated cylinder being used
to calibrate the carbonated water module. The larger the
volume dispensed, the more accurate the results. Use the
example
150 ml
.
6.
With the graduated cylinder placed in a position below the
nozzle, press the Start Purge button. The unit will dispense
the volume designated in the previous step.
A
B
C
D
Increase
Decrease
A. Flow Control
B. Valve Retainer
C. Solenoid
D. Valve Body
7. Examine the dispensed volume in the graduated cylinder.
If the dispensed volume does not match the value (
150 ml
)
entered on the screen in step 5, remove the protective cap
for the corresponding valve and use a screwdriver to adjust
the carbonated water flow control. (See Plumbing Diagram
on page 27 for reference).
8.
Repeat steps 6 and 7 until the designated volume of
150 ml
in step 5 is achieved.
9.
Repeat steps 2-8 for the plain water module, if present.
Each brand has a default water type and ratio already
set when they are selected. The water type and ratio
can be adjusted if necessary, however, adjusting the
ratio here is purely representational and does not
set the ratio for the finished drink. Adjust the ratio by
selecting the Ice or No Ice ratio using the buttons in
the upper right corner of the screen, or by manually
adjusting the ratio by tapping the number and entering
the new value on the keypad.
NOTE