22
Following sanitization, rinse with end-use product
until there is no aftertaste. Do not use a fresh water
rinse. This is a nsf requirement. Residual sanitizing
solution left in the system creates a health hazard.
!
CAUTION
Cleaning and Sanitizing Nozzle
1. Disconnect power, so as to not activate valve while
cleaning.
2.
Remove outer nozzle by twisting counter clockwise and
pulling down.
4. Wash nozzle with cleaning solution then immerse in
sanitizing solution and let sit for fifteen (15) minutes.
5. Set nozzle aside and let air dry.
DO NOT
rinse with water
after sanitizing.
6.
Using a soft, clean cloth and cleaning solution, clean the
nozzle injectors.
7.
Using a soft, clean cloth sanitize the nozzle injectors and let
air dry.
8.
Reconnect nozzle.
9. Connect power.
10. Taste the drink to verify that there is no off-taste. If off-taste
is found, sanitize the nozzle and nozzle injectors again.
A. Nozzle
A
3.
Rinse nozzle with warm water.
Cleaning and Sanitizing Product Lines
1. Disconnect product lines from BIB’s or other product supply.
2. Place product lines, with BIB connectors, in a bucket of
warm water.
3.
Activate each valve to fill the lines with warm water and
flush out product remaining in the lines.
4. Prepare Cleaning Solution described above.
5. Place product lines, with BIB connectors, into cleaning
solution.
6. Activate each valve until lines are filled with cleaning
solution then let stand for ten (10) minutes.
7. Flush out cleaning solution from the syrup lines using clean,
warm water.
8. Prepare Sanitizing Solution described above.
9. Place product lines into sanitizing solution and activate
each valve to fill lines with sanitizer. Let sit for ten (10)
minutes.
10.
Reconnect product lines to BIB’s and draw drinks to flush
solution from the dispenser.
11. Taste the drink to verify that there is no off-taste. If off-taste
is found, flush product system again.
Following sanitization, rinse with end-use product
until there is no aftertaste. Do not use a fresh water
rinse. This is a NSF requirement. Residual sanitizing
solution left in the system creates a health hazard.
!
CAUTION