Read This Manual
This manual was developed by Lancer Corporation as a reference guide for the owner/operator and installer
of this dispenser. Please read this manual before installation and operation of this dispenser. Please see
pages 22-24 for troubleshooting or service assistance. If the service cannot be corrected please call your
Service Agent or Lancer Customer Service. Always have your model and serial number available when you
call.
INSTALLATION
Unpacking the Dispenser
1. Cut package banding straps and remove.
2. Open the box and remove the accessory kit and loose
parts.
3. Carefully remove the dispenser from the corrugated
shipping carton and place on a flat surface taking care to
not scratch the plastic covers.
Inspect unit for concealed damage. If evident, notify
delivering carrier and file a claim against the same.
NOTE
Selecting/Preparing a Counter Location
1. Select a location that is in close proximity to a properly
grounded electrical outlet, within 1.5 m (5 ft) of a drain, and
a water supply that meets the requirements shown in the
Specifications section found on page 4.
2.
Select a location that utilizes the clearances/space required
for installation.
Inspect the counter location where the unit is to be
installed. Verify the selected counter is strong enough
to safely support the weight of the installed unit, after
the cutout for the unit is made. The ideal counter for
installation should measure at least 25 mm (1 inch)
thick.
!
ATTENTION
3. Select a location for the remote chiller system or carbonator
(if nessesary), syrup pumps, CO
2
tank, product containers,
and water filter (recommended).
4.
Using Counter Cutout Template provided, cut out required
opening for the drip tray and tower installation in the
designated dispenser location.
To assure that beverage service is accessible to all
customers, Lancer recommends that counter height
and equipment selection be planned carefully. The
2010 ADA Standards for Accessible Design states that
the maximum reach height from the floor should be no
more than 1.2 meters (48 inches) if touch point is less
than 254 mm (10 inches) from the front of the counter,
or a maximum of 1.17 meters (46 inches) if the touch
point is more than 254 mm (10 inches) and less than
685 mm (27 inches) from the front of the counter. For
more information about the customer’s legal
requirements for the accessibility of installed
equipment, refer to 2010 ADA Standards for
Accessible Design - http://www.ada.gov.
NOTE
6
Min: 20 mm
Max: 225 mm
Min: 50 mm
Max: 42 mm
Max: 850 mm
A. Drain Tube
B. Inlet Tubes
A
B