15
Calibrating Flavor Modules
Finished drink flow rate = 44 ml/sec
Ratio = 25:1
44 ml/sec X 1 / (25 + 1) =
1.69 ml/s bonus flavor flow rate
EXAMPLE
A. Enter Flow Rate C. Start Purge Button
B. Timer Icon
D. Unit Icon
A
B
C
1.
From the Maintenance menu, press the Calibrate tab on the
far left side of the screen and press the Calibrate button for
any designated flavor module.
2.
Enter the flow rate in milliliters per second (ml/sec). This
number is based on the target drink flow rate of 1.5 oz/sec
and a designated flavor ratio. (See product container for
designated ratio)
D
3. Set the Timer to the ON position and select milliliters (ml) as
the desired unit of measurement.
4.
Using the keypad, enter a specific volume to be dispensed
based on the size of the graduated cylinder being used to
calibrate the flavor module.
5. With the graduated cylinder placed in a position below the
nozzle, press the Start Purge button. The unit will dispense
the volume designated in the previous step.
6.
Examine the dispensed volume in the graduated cylinder.
If the dispensed volume does not match the value entered
on the screen in step 5, remove the protective cap for the
corresponding valve and use a screwdriver to adjust the
carbonated water flow control. (See Plumbing Diagram on
page 27 for reference).
A
B
C
D
Increase
Decrease
A. Flow Control
B. Valve Retainer
C. Solenoid
D. Valve Body
7.
Repeat steps 6 and 7 if any more bonus flavor flow
adjustment is necessary.
8.
Repeat steps 2-8 for any remaining bonus flavor module.
A
B
C
D
Increase
Decrease
A. Flow Control
B. Valve Retainer
C. Solenoid
D. Valve Body
8. Verify that the syrup level is even with the water level in the
ratio cup. If the dispensed syrup and water levels are not
level, remove the protective cap from the corresponding
valve and use a screwdriver to adjust the brand syrup flow
control. (See Plumbing Diagram on page 27 for reference).
9.
Repeat steps 7 and 8 if any more brand syrup flow
adjustment that is necessary.
10.
Repeat steps 2-9 for the remaining brand syrup modules.
11.
Press the Maintenance button to return to the Maintenance
screen and then press the Menu button to return to the
Service menu.