1. GENERAL INFORMATION
•
Carefully read the warnings in this instruction booklet
•
Once the boiler is installed, show its operation to the user and deliver this ins-
truction manual, which is an integral and essential part of the product and must
be carefully stored so that it can be consulted at any time.
•
Installation and maintenance must be carried out byprofessionally qualifi ed per-
sonnel, according to current regulations and the manufacturer’s instructions. It
is forbidden to handle any sealed regulation device.
•
Incorrect installation or poor maintenance can causedamage or physical injury.
The manufacturer declines any responsibility for damage caused by errors in
installation and use or by failure to follow themanufacturer’s instructions.Before
carrying out any cleaning or maintenance operation, disconnect the unit fromthe
power supply using the system switch and/or the special cut-off devices.
•
Before carrying out any cleaning or maintenance operation, disconnect the unit
fromthe power supply using the system switch and/or the special cut-off devices.
• In case of a fault and/or poor operation, deactivate the unit and do not try to
repairit or directly intervene. Contact professionally qualifi ed personnel. Any re-
pair/re-placement of the products must only be carried out by qualifi ed personnel
using genuine parts. Failure to comply with the above can compromise the safe-
ty of the unit.This unit must only be used for its intended purpose.
•
This unit must only be used for its intended purpose
•
Any other use is deemed improper and therefore hazardous.
• Do not leave the packaging elements within the reach of children as they are
dangerous.
• The unit can be used by children aged at least 8 years and by persons with
reducedphysical, sensory or mental capabilities, or lacking experience or the
necessary knowledge, only if under supervision or they have received instruc-
tions on its safeuse and the related risks. Children must not play with the unit.
Cleaning and maintenance intended to be done by the user can be carried out
by children aged at least8 years only if under supervision.
• The unit and its accessories must be appropriately disposed of in compliance
withcurrent regulations.
•
The images given in this manual are a simplifi ed representation of the product.
Inthis representation there may be slight and insignifi cant differences with res-
pect tothe product supplied.
2.OPERATING INSTRUCTIONS
2.1 Introduction
Dear Customer,
Thank you very much for choosing
KYRA D 30 UNIT COND
, a
LAMBORGHINI
standing boiler with advanced design, state-of-the-art technology, high reliability
and constructive quality. Please read this manual carefully, as it provides important
information about installation, use and maintenance.
KYRA D 30 UNIT COND
is a thermal generator for heating, with
condensation,
high performance and low emission level.
The
boiler body
is made of carbon steel and high quality stainless steel; inside it
houses a stainless steel coil for DHW production.
The burner is pressurized.
We ask you to carefully read this manual as it has important information about ins-
tallation, use and maintenance.
2.2 Control panel
Panel
fi
g.1 – Control panel
Panel key
1 =
DHW temperature setting decrease button
2 =
DHW temperature setting increase button
3 =
Heating system temperature setting decrease button
4 =
Heating system temperature setting increase button
5 =
Display
6 =
Summer / Winter mode selection button
7 =
Economy / Comfort mode selection button
8 =
Reset button
9 =
Unit On / Off button
10 =
“Sliding Temperature” menu button
11 =
Set DHW temperature reached
12 =
DHW
symbol
13 =
DHW
mode
14 =
DHW outlet temperature / setting
15 =
Eco (Economy) or Comfort mode
16 =
External sensor temperature (with optional external probe)
17 =
Appears on connecting the external Probe or the Remote Timer Control (optionals)
18 =
Room temperature (with optional Remote Timer Control)
19 =
Burner On
20 =
Antifreeze operation
21 =
Heating system pressure
22 =
Fault
23 =
Heating delivery temperature/setting
24 =
Heating symbol
25 =
Heating
mode
26 =
Set heating delivery temperature reached
27 =
Summer
mode
NOTE: The series boiler is con
fi
gured for its sole use in heating, so
the symbols referring to DHW will not appear on the display. These
symbols will appear when the boiler is con
fi
gured for use with ACS.
Indication during operation
Heating
A heating demand (generated by the Room Thermostat or Remote Timer Control)
is indicated by fl ashing of the hot air above the radiator (details 24 and 25 - fi g.1).
The heating graduation marks (detail 26 - fi g.1) light up as the heating sensor tem-
perature reaches the set value.
fi
g.2
DHW (Comfort)(Optional Con
fi
guration)
A DHW demand (generated by drawing domestic hot water) is indicated by fl ashing
ofthe hot water under the tap (details 12 and 13 - fi g.1).
The DHW graduation marks (detail 11 - fi g.1) light up as the DHW sensor tempera-
turereaches the set value.
fi
g.3
Exclusion of the accumulator (Economy)
The operation of the accumulator (heating and maintenance in temperature) can be
deactivated by the user. In such a case, there is no sanitary hot water supply. When
the accumulator is activated (default option), the COMFORT symbol appears on the
display (15 - fi g.1); if it is deactivated, the ECO symbol (15-fi g.1) is displayed. To
deactivate the heater and set the ECO mode, press the eco / comfort key (7- fi g.1).
To return to COMFORT mode, press the eco / comfort key again (7- fi g.1)
fi