27
F1
9.2) Adjusting the device with remote programming via digital selector
For the remote programming of DIP S1 and of potentiometers from TM1 to TM5 to become operative,
DIP12 of S1 must be
set to the ON position.
The programming of all other parameters does not depend on DIP 12 of S1.
Comply with the following instructions to access the programming mode:
A) Move the selector’s locking key to the functions locked position .
B) Press the selector’s SET button and keep it depressed
C) Move the locking key back to the functions free position .
D) Release the SET button .
E) The yellow leds of the inputs will come on from left to right in sequence, to indicate that the data are being loaded (UPLOAD).
F) Once the UPLOAD phase has terminated, the red BATTERY led and the yellow led will come on.
G) The battery led shows that work is being carried out on DIP-SWITCH S1 while the yellow led indicates:
G1)that DIP1 of S1 is in the ON position issues an tunbroken light
G2)that DIP1 of S1 is in the OFF position if the led flashes.
H) Press the door free button to change the status of the DIP-SWITCH (ON - OFF) .
I) Press button F1 to move to DIP2 of S1 .
L) Repeat the last operation to move to the other DIP-SWITCHES of S1.
M) Refer to sections 6 and 7 for the meaning of the DIP-SWITCHES.
N) To operate on DIP-SWITCH S2, press the SET button. The LINE led will come on.
O) Repeat the operations as given for MINIDIP S1 to select and change the status of the individual DIP-SWITCHES.
P) Press the SET button to move to POTENTIOMETER TM1. The 2-WAY traffic led will come onI .
Q) When the potentiometers are being used, the input leds form a scale to indicate the set value.
R) To change the value of the selected potentiometer, press:
R1) the DOOR FREE button to decrease the value.
R2) the F1 button to increase the value.
S) Press the SET button to move to POTENTIOMETER TM2.
T) Repeat this last operation to move to the other potentiometers.
U) Refer to section 8 for the meaning of the potentiometers.
V) Comply with the following instructions to quit the programming phase and memorize the changed values:
V1) Move the selector’s locking key to the functions locked position
V2) Press the selector’s SET button and keep it depressed del selettore.
V3) Move the locking key back to the functions free position .
V4) Release the SET button .
V5) The leds of the inputs will come on from right to left in sequence to indicate DOWNLOAD.
V6) The control unit will issue 2 bips once the DOWNLOAD phase has terminated
V7) The selector will set back to the normal operating mode.
Z) Comply with the following instructions to quit the programming phase and without memorizing the changed values
Z1) Move the selector’s locking key to the functions locked position .
Z2) Move the locking key back to the functions free position .
Z3) The selector returns on normal operation and the control unit issues one single bip.