29
AUTOMATION "1"
AUTOMATION "2"
14.3) INITIAL SETUP
From the general programming menu, the F1 button allows moving forward among menu symbols.
Select the INITIAL SETUP symbol.
Press quickly the ENTER button to enter the “Initial setup” section.
If the digital selector ET-DSEL is connected to two automatic doors, select by pressing the F3 button
once whether the initial set‑up concerns the automation of door 1 or door 2.
The initial set‑up must be carried out separately on each automation.
Type the 10‑character technical password to access setup.
The default technical password used by Label for the digital selectors ET-DSEL is “A-A-A-A-A-A-A-
A‑A‑A”
Press the button in correspondence with letter A, an asterisk appears on the position of the first letter;
repeat this operation for all the other characters required.
If the password you entered is correct, you enter the configuration section of the set-up; if the
password you entered is incorrect, you are returned to the general programming menu.
It is advisable to change the technical default password. See para. "Password Management".
BEFORE STARTING THE SET-UP CYCLE, MOVE THE DOOR TO CLOSED POSITION.
THE AUTOMATION AUTOMATICALLY DETECTS THE CORRECT DIRECTION OF TRAVEL DURING THE SET-UP CYCLE.
Only if the function S02 was set to OFF
Only select ON if a double electric lock for pharmacy function is installed in the automation.
Please refer to the paragraph "PHARMACY FUNCTION".
If no pharmacy electric lock is installed keep the setting to OFF.
FULL SETUP:
mandatory operation on first installation of the automation.
PARTIAL SETUP:
operation that enables to repeat just leaf run learning if the mechanical limit spot has been
moved, without changing any function previously set.
WARNING!
Partial set-up does not work in a new automation on first installation. In this case, if it the partial option is selected,
the buzzer of the control unit will report the error by emitting a sound for 4 seconds.
Press the button F1 to select the FULL SET‑UP.
In this section, the buttons F1 / F3 allow selecting the function OFF/ON status, while the button
allows going to the following function.
Press the button F2 to return to the previous function.
Select the model of the automation:
ON = ETERNA 150
OFF = ETERNA 150 / 300T
Select the model of the installed electric lock.
OFF = mod. FAIL SECURE or BISTABLE
ON = mod. FAIL SAFE
If the automation is not equipped with an electric lock, keep the setting to OFF.
BATTERY MODULE
OFF = BATTERY NOT PRESENT
ON = BATTERY PRESENT
Select ON only if a closure safety sensor has been installed on input E.C.1.